UAS CLARCOR SMOG-HOG MSH Series Скачать руководство пользователя страница 24

UNITED AIR SPECIALISTS, INC.

LIMITED WARRANTY

UAS  warrants  to  the  original  purchaser  that  all  equipment  will  be  free  from  defects  in  materials  and 
workmanship for one year from the date of shipment from UAS (three years for Smokeeter® and VisionAir™ 
models other than CC and DC series) and that major structural components on SFC and MCB series will be 
free from defects in materials and workmanship for ten years from the date of shipment from UAS.  This 
warranty applies only if equipment is properly installed, maintained, and operated under normal conditions 
and does not apply to damage caused by corrosion, abrasion, abnormal use or misuse, misapplication, or 
normal wear and tear.  This warranty will be void with respect to equipment that is subject to unauthorized 
repairs or modifications.  UAS makes no warranty as to goods manufactured or supplied by others.  This 
warranty  is  subject  to  any  limitations  in  UAS’  quotation  and  may  not  be  modified  except  by  a  written 
instrument signed by the President or Vice President of Sales of UAS.

THIS  WARRANTY  IS  EXCLUSIVE  AND  IN  LIEU  OF  ALL  OTHER  WARRANTIES,  WHETHER 
WRITTEN, ORAL OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, 
FITNESS FOR A PARTICULAR PURPOSE OR NONINFRINGEMENT.

As  Purchaser’s  exclusive  remedy  for  any  defects  in  the  equipment,  UAS  will  exchange  or  repair  any 
defective parts during the warranty period, provided such parts are returned, prepaid, to UAS’ factory.  The 
obligation of UAS is limited to furnishing replacement parts F.O.B. UAS’ factory or making repairs at UAS’ 
factory of any parts that are determined, upon inspection by UAS, to be defective.  In no event will UAS be 
responsible for labor or transportation charges for the removal, reshipment or reinstallation of the parts.

IN  NO  EVENT  WILL  UAS  BE  RESPONSIBLE  FOR  ANY  SPECIAL  OR  CONSEQUENTIAL 
DAMAGES.

WARRANTY REGISTRATION: Register online at www.uasinc.com/registration.aspx

4440 Creek Road • Cincinnati, Ohio 45242 US

A

National Phone: 1-800-252-4647

T

elephone: (513) 891-0400 • Fax: (513) 891-4882

www

.uasinc.com

©2015 United Air Specialists

Part No. 44-10510

03/15

Содержание CLARCOR SMOG-HOG MSH Series

Страница 1: ...Industrial Electrostatic Air Cleaner l SMOG HOG MSH Model OWNER S MANUAL ...

Страница 2: ...ce have the following information available when contacting UAS UAS ORDER _________________________________________________________________ UNIT MODEL ________________________________________________________________ UNIT SERIAL _________________________________________________________________ SYSTEM ACCESSORIES ______________________________________________________________________________ ________...

Страница 3: ...G 2 5 1 Normal Maintenance 2 5 2 Manual Cleaning of SMOG HOG Components 3 5 3 Manual Cleaning Methods 3 5 4 Appearance Of Components After Cleaning 4 5 5 Replacing Damaged Ionizer Wires 4 6 TROUBLESHOOTING 4 6 1 Tools Required 4 6 2 Perform Before Troubleshooting 4 6 3 Troubleshooting Procedures 5 6 4 Troubleshooting Table 8 7 REPLACEMENT PARTS 9 7 1 Replacement Parts List 9 8 FIGURES 10 12 9 WIRI...

Страница 4: ...cessive accumulation which may result in flash over or fire damage The air cleaner should not be used for support of personnel or material Operate only in a safe and serviceable condition DANGER WARNING CAUTION C A U T I O N This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and th...

Страница 5: ...en using power pack 21 1216 and 5 6mA when using power pack 21 1234 In the event of a short circuit or other overload condition the power supply is designed to cause the high voltage to collapse When the voltage collapses the indicator light will blink When the overload is removed the voltage will automatically build up to normal and the indicator light will illuminate The power supply is self pro...

Страница 6: ...ions Periodically momentary shorts will occur indicated by the flickering indicator light If the light is dim fails to glow or continues to flicker the components may need cleaning or servicing see Cleaning Instructions Section 5 2 and 5 3 5 MAINTENANCE AND MANUAL CLEANING 5 1 Normal Maintenance Once the unit is operational periodic maintenance is necessary to assure proper performance Follow a re...

Страница 7: ...mation or some other undesirable condition Time is necessary for effective cleaning Soaking may seem slower and less effective than high impingement and or hot water above 180 F for cleaning action so personnel should be forewarned about using excessive pressure or temperature to shortcut the cleaning process High pressure or stream spray cleaning until plate edges are shiny is not effective Not o...

Страница 8: ...kets are cleaned and intact 3 Component tracks are free of contaminant build up for unicell grounding 4 Module drain sump is cleaned and free flowing 5 Interior is free of extreme contaminant build up 6 Blower wheel is free of contaminant build up 5 5 REPLACING DAMAGED IONIZER WIRES 1 Remove the damaged wire from each spring Also replace spring if it is damaged 2 Loop one end of the new wire over ...

Страница 9: ...high voltage The grounding procedure statement is not identified within the troubleshooting steps but should be performed The power pack total current output is limited to a maximum of 5 milliamps to assure personnel safety A high voltage probe is required to measure high voltages to the ionizer and collector circuits to the unit As an accessory a high voltage probe can be purchased for a multimet...

Страница 10: ...ar itself by removing the unicell s from the module and then installing the unicell s back into the module Place MSH off connect all wires which have been disconnected and install unicell s b Indicator light is illuminated with the high voltage wire 7 connected to the collector cell connector on the power pack Place MSH off and connect high voltage wire 8 to the ionizer connector on the power pack...

Страница 11: ... 11 8 KVDC If the ionizer voltage is below specifications refer step 2 Ionizer Conditions Causing Failure Low ionizer voltage will decrease the collector cell voltage but low cell voltage will not affect the ionizer voltage 4 Place the tip of the high voltage probe to the collector cell door feed through insulator bolt The high voltage measurement should be 5 0 to 7 3 KVDC If the collector cell vo...

Страница 12: ...fective Unicell dirty Unicell malfunction Unicell installed backwards or upside down High voltage contacts dirty Loss of input voltage Unicell malfunctioning Power supply defective POSSIBLE SOLUTIONS Replace lamp Check connection to lamp Check power supply Replace air mover Clean foreign object from air mover Replace control switch Check connection at control switch Correct wiring Engage safety in...

Страница 13: ...r 33Ͳ10116 33Ͳ10121 2 Unicell 02Ͳ10429Ͳ0001ͲS 02Ͳ1921ͲS 3 Mesh AfterͲFilter 33Ͳ10110 33Ͳ10120 4 Inlet Cone Ring 32Ͳ10053 32Ͳ10067 5 Motorized Impeller Fan 32Ͳ10052 32Ͳ10065 6 Ionizer Spring 36Ͳ0068 36Ͳ0068 7 Cell Spring 36Ͳ0012 36Ͳ0012 8 Cell Ground Spring 36Ͳ0016 36Ͳ0016 9 Interlock Switch 20Ͳ0005 20Ͳ0005 10 Filter Door Latch 39Ͳ10055 39Ͳ10055 11 Feed Through Insulator 37Ͳ0026 37Ͳ0026 12a Power P...

Страница 14: ...10 Revised 03 15 SMOG HOG Electronic Air Cleaner Figure 1 Unit Components ...

Страница 15: ...1 Revised 03 15 SMOG HOG Electronic Air Cleaner Figure 2 Drain Loop Assembly Figure 4 Replacing Ionizer Section Figure 3 Ionizer and Cell Voltage Measurement Figure 5 Grounding The Collector Cell Section ...

Страница 16: ...12 Revised 03 15 SMOG HOG Electronic Air Cleaner Figure 6 Grounding the Ionizing Section Figure 7 Power Pack Input Output Connections ...

Страница 17: ...13 Revised 03 15 SMOG HOG Electronic Air Cleaner MSH 05 ...

Страница 18: ...14 Revised 03 15 SMOG HOG Electronic Air Cleaner MSH 05 M ...

Страница 19: ...15 Revised 03 15 SMOG HOG Electronic Air Cleaner MSH 11 ...

Страница 20: ...16 Revised 03 15 SMOG HOG Electronic Air Cleaner MSH 11 M ...

Страница 21: ...17 Revised 03 15 SMOG HOG Electronic Air Cleaner MSH 11 w Optional ON OFF Switch ...

Страница 22: ...18 Revised 03 15 SMOG HOG Electronic Air Cleaner MSH 05 1PH Interconnect MSH 11 1PH Interconnect ...

Страница 23: ...19 Revised 03 15 SMOG HOG Electronic Air Cleaner MSH 05 3PH Interconnect MSH 11 3PH Interconnect ...

Страница 24: ...dified except by a written instrument signed by the President or Vice President of Sales of UAS THIS WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER WRITTEN ORALOR IMPLIED INCLUDINGANYIMPLIED WARRANTYOF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NONINFRINGEMENT As Purchaser s exclusive remedy for any defects in the equipment UAS will exchange or repair any defective part...