SMoG-HoG

®

electronic air cleaner

1

1.  IMPORTANT NOTICE

this manual contains important safety information and 

precautionary measures. it is impossible to list all potential 

hazards associated with every air cleaning system in 

each application. Proper use of the equipment must be 

discussed with United Air Specialists, Inc. (UAS) or your local 

Representative. Operating personnel must be aware of, and 

adhere to, the most stringent safety procedures.

  

Unit Specifications:

for indoor use only 

* Weights are approximate and may not reflect final unit weight

2.  DESCRIPTION 

(See figure 1)

This unit is a self-contained, two-stage, air cleaner designed 

to remove dry or oily airborne contaminants from industrial 

work areas. operating on the principle of electrostatic 

precipitation, it pulls air past a mist-stop pre-filter, charges and 

collects airborne particulate, then exhausts clean air to the 

environment.
Mist-stop pre-filters serve the dual purpose of trapping 

large particles and diffusing the air stream evenly into the 

precipitator components at low, controlled velocity. Air passes 

through an ionizing section where nearly all particulate is 

charged; then on to a collecting section where charged 

particles are repelled from similarly charged plates and drawn 

to ground plates. agglomerated particles separated from 

collection plates during unit startup are trapped on an after-

filter, allowing clean air to pass through the system blower at 

all times.
the Model MSH may be ducted directly to the contaminant 

source or un-ducted to remove particles from the general 

environment.

  2.1  SYSTEM COMPONENTS

1. Mist Stop Filter

the Mist Stop filter is a pre-filter used to remove large 

particulate and aids in diffusing the air entering the eSP 

section. 

2. High Voltage Power Supply

the power pack contains the necessary components to 

convert customer provided input power (see section 1) 

 

to the high-voltage Dc required for the ionizer and  

collection cell.

To ensure both equipment and personnel safety, the power 

supply high voltage output circuit is limited to a maximum 

of 5.0ma when using power-pack 21-1216 and 5.6ma when 

using power-pack 21-1234.

In the event of a short circuit or other overload condition, 

the power supply is designed to cause the high voltage to 

collapse. When the voltage collapses, the indicator light 

will blink. When the overload is removed, the voltage will 

automatically build up to normal and the indicator light will 

illuminate. the power supply is self-protecting  

against overload. 

When the power is removed from the power supply circuit, 

an internal resistor bleeds off the residual charge on the 

collection cell. As a precaution, when the access door is 

opened, the blade of an insulated handle screwdriver 

 

should be used to ground components before removal  

(see grounding procedure, figures 5 & 6).

3. Unicell Ionizing & Collection Section

the ionizing section supports thin tungsten wires which carry 

a positive charge of approximately 11 KVDC. This section 

electrically charges (ionizes) the contaminated particles being 

pulled through the unit.
the collection section contains plates alternately charged to 

a positive voltage of approximately 5.5 KVDC. This section 

collects charged particles passing through the ionizer.

4. Air Mover

The motor/blower pulls in the contaminated air and exhausts 

the clean air through the outlet.

3.  INSTALLATION

  3.1  INSPECTION NOTE

Upon receipt of your unit, check for any shipping damage. 

a damaged carton indicates that the equipment may have 

received rough handling during shipping that may have 

caused possible internal damage. notify your delivery carrier 

and enter a claim if any damage is found.

  3.2  INSTALLATION PLANNING

Locating the Unit: 

consideration must be given to the

placement of the precipitator to maximize its effectiveness. 

When your SMoG-HoG® is used as a ducted source 

collector, the enclosure or pickup hood design is important 

for adequate capture of contaminants. Model MSH blowers 

have limited static pressure capacity. check with factory for 

anticipated duct losses in excess of 0.5 inWC (12.7 mmWC).

CFM

CMH

lbs

kg

HP

kW

V/PH/Hz

FLA

MSH-05-H

MSH-05-V

MSH-05-M-H

MSH-05-M-H

MSH-11-H

MSH-11-V

MSH-11-M-H

MSH-11-M-V

1,100 1,870

Electrical Service

0.25

0.2

1.45

1.1

100-120/1/60

3-wire

230/1/60

4-wire

5

7

8

192

3

.

5

5

2

1

5

7

2

2.3

9

.

2

9

7

5

7

1

Weight*

Blower Size

Model

115

52

Airflow

500

850

Содержание CLARCOR SMOG-HOG MSH Series

Страница 1: ...Industrial Electrostatic Air Cleaner l SMOG HOG MSH Model OWNER S MANUAL ...

Страница 2: ...ce have the following information available when contacting UAS UAS ORDER _________________________________________________________________ UNIT MODEL ________________________________________________________________ UNIT SERIAL _________________________________________________________________ SYSTEM ACCESSORIES ______________________________________________________________________________ ________...

Страница 3: ...G 2 5 1 Normal Maintenance 2 5 2 Manual Cleaning of SMOG HOG Components 3 5 3 Manual Cleaning Methods 3 5 4 Appearance Of Components After Cleaning 4 5 5 Replacing Damaged Ionizer Wires 4 6 TROUBLESHOOTING 4 6 1 Tools Required 4 6 2 Perform Before Troubleshooting 4 6 3 Troubleshooting Procedures 5 6 4 Troubleshooting Table 8 7 REPLACEMENT PARTS 9 7 1 Replacement Parts List 9 8 FIGURES 10 12 9 WIRI...

Страница 4: ...cessive accumulation which may result in flash over or fire damage The air cleaner should not be used for support of personnel or material Operate only in a safe and serviceable condition DANGER WARNING CAUTION C A U T I O N This is the safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others All safety messages will follow the safety alert symbol and th...

Страница 5: ...en using power pack 21 1216 and 5 6mA when using power pack 21 1234 In the event of a short circuit or other overload condition the power supply is designed to cause the high voltage to collapse When the voltage collapses the indicator light will blink When the overload is removed the voltage will automatically build up to normal and the indicator light will illuminate The power supply is self pro...

Страница 6: ...ions Periodically momentary shorts will occur indicated by the flickering indicator light If the light is dim fails to glow or continues to flicker the components may need cleaning or servicing see Cleaning Instructions Section 5 2 and 5 3 5 MAINTENANCE AND MANUAL CLEANING 5 1 Normal Maintenance Once the unit is operational periodic maintenance is necessary to assure proper performance Follow a re...

Страница 7: ...mation or some other undesirable condition Time is necessary for effective cleaning Soaking may seem slower and less effective than high impingement and or hot water above 180 F for cleaning action so personnel should be forewarned about using excessive pressure or temperature to shortcut the cleaning process High pressure or stream spray cleaning until plate edges are shiny is not effective Not o...

Страница 8: ...kets are cleaned and intact 3 Component tracks are free of contaminant build up for unicell grounding 4 Module drain sump is cleaned and free flowing 5 Interior is free of extreme contaminant build up 6 Blower wheel is free of contaminant build up 5 5 REPLACING DAMAGED IONIZER WIRES 1 Remove the damaged wire from each spring Also replace spring if it is damaged 2 Loop one end of the new wire over ...

Страница 9: ...high voltage The grounding procedure statement is not identified within the troubleshooting steps but should be performed The power pack total current output is limited to a maximum of 5 milliamps to assure personnel safety A high voltage probe is required to measure high voltages to the ionizer and collector circuits to the unit As an accessory a high voltage probe can be purchased for a multimet...

Страница 10: ...ar itself by removing the unicell s from the module and then installing the unicell s back into the module Place MSH off connect all wires which have been disconnected and install unicell s b Indicator light is illuminated with the high voltage wire 7 connected to the collector cell connector on the power pack Place MSH off and connect high voltage wire 8 to the ionizer connector on the power pack...

Страница 11: ... 11 8 KVDC If the ionizer voltage is below specifications refer step 2 Ionizer Conditions Causing Failure Low ionizer voltage will decrease the collector cell voltage but low cell voltage will not affect the ionizer voltage 4 Place the tip of the high voltage probe to the collector cell door feed through insulator bolt The high voltage measurement should be 5 0 to 7 3 KVDC If the collector cell vo...

Страница 12: ...fective Unicell dirty Unicell malfunction Unicell installed backwards or upside down High voltage contacts dirty Loss of input voltage Unicell malfunctioning Power supply defective POSSIBLE SOLUTIONS Replace lamp Check connection to lamp Check power supply Replace air mover Clean foreign object from air mover Replace control switch Check connection at control switch Correct wiring Engage safety in...

Страница 13: ...r 33Ͳ10116 33Ͳ10121 2 Unicell 02Ͳ10429Ͳ0001ͲS 02Ͳ1921ͲS 3 Mesh AfterͲFilter 33Ͳ10110 33Ͳ10120 4 Inlet Cone Ring 32Ͳ10053 32Ͳ10067 5 Motorized Impeller Fan 32Ͳ10052 32Ͳ10065 6 Ionizer Spring 36Ͳ0068 36Ͳ0068 7 Cell Spring 36Ͳ0012 36Ͳ0012 8 Cell Ground Spring 36Ͳ0016 36Ͳ0016 9 Interlock Switch 20Ͳ0005 20Ͳ0005 10 Filter Door Latch 39Ͳ10055 39Ͳ10055 11 Feed Through Insulator 37Ͳ0026 37Ͳ0026 12a Power P...

Страница 14: ...10 Revised 03 15 SMOG HOG Electronic Air Cleaner Figure 1 Unit Components ...

Страница 15: ...1 Revised 03 15 SMOG HOG Electronic Air Cleaner Figure 2 Drain Loop Assembly Figure 4 Replacing Ionizer Section Figure 3 Ionizer and Cell Voltage Measurement Figure 5 Grounding The Collector Cell Section ...

Страница 16: ...12 Revised 03 15 SMOG HOG Electronic Air Cleaner Figure 6 Grounding the Ionizing Section Figure 7 Power Pack Input Output Connections ...

Страница 17: ...13 Revised 03 15 SMOG HOG Electronic Air Cleaner MSH 05 ...

Страница 18: ...14 Revised 03 15 SMOG HOG Electronic Air Cleaner MSH 05 M ...

Страница 19: ...15 Revised 03 15 SMOG HOG Electronic Air Cleaner MSH 11 ...

Страница 20: ...16 Revised 03 15 SMOG HOG Electronic Air Cleaner MSH 11 M ...

Страница 21: ...17 Revised 03 15 SMOG HOG Electronic Air Cleaner MSH 11 w Optional ON OFF Switch ...

Страница 22: ...18 Revised 03 15 SMOG HOG Electronic Air Cleaner MSH 05 1PH Interconnect MSH 11 1PH Interconnect ...

Страница 23: ...19 Revised 03 15 SMOG HOG Electronic Air Cleaner MSH 05 3PH Interconnect MSH 11 3PH Interconnect ...

Страница 24: ...dified except by a written instrument signed by the President or Vice President of Sales of UAS THIS WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER WRITTEN ORALOR IMPLIED INCLUDINGANYIMPLIED WARRANTYOF MERCHANTABILITY FITNESS FOR A PARTICULAR PURPOSE OR NONINFRINGEMENT As Purchaser s exclusive remedy for any defects in the equipment UAS will exchange or repair any defective part...

Отзывы: