Crossflow Dust Collector
PROBLEM
POSSIBLE CAUSE
POSSIBLE SOLUTIONS
Blower motor won’t start or will
not stay running.
No voltage to system.
Check primary voltage to motor circuits for
proper voltage on all legs.
Improper electrical wiring.
Check and correct internal motor wiring for
proper connections based on the incoming
line voltage. Wiring diagram is found on
lead access plate.
Starter overloads tripped.
Check for proper motor starter overload
rating against full load amps on the motor
nameplate. Adjust or replace overloads as
required.
Dust emissions from clean air
discharge.
Filters installed improperly.
Inspect and reinstall cartridge filters. Make
sure the cambars are engaged.
Filters damaged.
Replace the damaged filter(s) with new
Nanofiber® cartridge filters.
Insufficient airflow.
Blower rotation is running in reverse.
Ensure blower is circulating clockwise from
drive side.
Air inlet(s) obstructed.
Inspect and clean all louver doors.
Filters plugged.
Refer to troubleshooting procedures for
continual pressure drop.
Continual, excessive pressure
drop (over 5") on filter monitor
panel.
Compressed air supply problems.
Check incoming compressed air for proper
pressure (90-110 PSIG [6.4-7.2 BAR]),
pulse flow (1.7 SCF standard cubic feet
[48.1 liters] per pulse) and pulse duration
(100 milli-seconds). Correct any problems.
Pulse cleaning system not
functioning properly.
Check incoming 110-115 VAC power to
cleaning control panel. Check for blown
fuse on panel. Replace if necessary.
Check for 110V output from timerboard. If
incoming voltage is correct and fuse is not
blown, replace timerboard.
DPC Panel not adjusted properly.
Refer to Section 6.2.2 of this manual for
proper setting of DPC Panel.
8. TROUBLESHOOTING GUIDE
Use the troubleshooting guide to correct any problems that occur with your dust collection unit. If the problem or
condition continues, contact UAS customer service at 1-800-252-4647.
Pulse system not adjusted
properly.
Pulse settings incorrect.
Adjust pulse duration to 0.100 seconds
(position 3). Adjust pulse delay to
10 seconds (position 2).
Filters are at the end of their
service life.
Replace filters with Protura® Nanofiber
filters from UAS. Each cartridge filter has a
part number affixed to the end cap.
Check for proper pulse valve operation.
Replace damaged parts as required.
Содержание CLARCOR MCB Series
Страница 1: ...Cross Ventilation Cartridge Dust Collector l MCB Series OWNER S MANUAL...
Страница 6: ...2 Revised 03 15 MCB Crossflow Dust Collector Figure 1 MCB Operation Detail 44 10343 0001...
Страница 9: ...5 Revised 03 15 MCB Crossflow Dust Collector Figure 3 MCB Installation Detail 44 10360 0001...
Страница 11: ...7 Revised 03 15 MCB Crossflow Dust Collector Figure 4 Motor Installation Diagram 44 10342 0001...
Страница 12: ...8 Revised 03 15 MCB Crossflow Dust Collector Figure 5 MCB Booth Assembly 44 10361 0001...
Страница 13: ...9 Revised 03 15 MCB Crossflow Dust Collector Figure 6 Booth Panel Interlock Connection...
Страница 15: ...11 Revised 03 15 MCB Crossflow Dust Collector Figure 7 MCB Pressure Gauge Installation 44 10350 0001...
Страница 17: ...13 Revised 03 15 MCB Crossflow Dust Collector Figure 8 Solenoid Wiring to Pulse Controls 61 10017 0001 REV B...
Страница 20: ...16 Revised 03 15 MCB Crossflow Dust Collector 9 ILLUSTRATED PARTS 6 and 9 Foot Wide Module...
Страница 22: ...18 Revised 03 15 MCB Crossflow Dust Collector 11 ILLUSTRATED PARTS 3 Foot Wide Module...