background image

19

Revised 03/15

MCB

Crossflow Dust Collector

12. MCB PARTS LIST

For 3 Foot Wide Modules

Item No. 

Part No. 

Description

MOTOR, 1750 RPM, (VOLTAGE & HORSEPOWER SPECIFIC)

DUST DRAWER ASSEMBLY

INLET LOUVER DOOR ASSEMBLY

DOOR GASKET, NEOPRENE SPONGE

0-8" DPC GAUGE (Not Shown)

0-8" DPM GAUGE (Not Shown)

VALVE, DIAPHRAGM, I" COMPRESSION, DM25

DIAPHRAGM VALVE REPAIR KIT, I" NPT (Not Shown)

MCB, FRONT PANEL ACCESS WDT, 3' MODULE

ACCESS PANEL GASKET, NEOPRENE SPONGE

ACCESS PANEL, ACOUSTICAL FOAM, 3' MODULE

AIR EXHAUST SCREEN, 3' MODULE

MOTOR/BLOWER MOUNTING PLATE

NOZZLE, PULSING SYSTEM

PULSE TIMER BOARD (Not Shown)

SOLENOID ENCLOSURE, 2 POSITION

SOLENOID REPAIR KIT (Not Shown)

SOLENOID VALVE REPLACEMENT (Not Shown)

FINISHING PLUG, 2 1/4" DIA.

SCREW, HEX WASHER, 5/16-18 x 3/4 LG, SWAGEFORM

BLOWER WHEEL

BLOWER INLET CONE

CARTRIDGE FILTER (VIEW LABEL ON END OF FILTER AND CONSULT UAS)

TUBE FITTING, 90 DEG ELBOW, I/8" NPT MALE x 1/4" TUBE

PLUG-PIPE, 1" NPT, BLACK IRON

LATCH/HANDLE, INLET LOUVER DOOR

BLOWER ASSEMBLY SEALANT, GORE-TEX

(CONSULT UAS)

02-10587-0001

02-10588-0001

42-0163

07-10010-A308

07-10009-A208

07-10002-0001

07-10003-0001

18-10635-0001

42-0163 

10-11656-0001

10-11657-0001

18-10636-0001

19-10016-0001

20-3048 

20-10076-0002

07-0133

20-1631

39-10015-2250

30-10054-0750

32-10032-31ST

32-10029-0003

33-10092-XX

38-0814

38-0829

39-10013-0001

42-0080

1

2

3A

3C

6

7

8

8A

10

10A

10B

11

18

19

20

21

21A

21B

23

24

25

26

27

30

31

32

34

Содержание CLARCOR MCB Series

Страница 1: ...Cross Ventilation Cartridge Dust Collector l MCB Series OWNER S MANUAL...

Страница 2: ...ation available when contacting UAS UAS ORDER __________________________________________________________ UNIT MODEL _ ________________________________________________________ UNIT SERIAL _ ___________...

Страница 3: ...5 1 1 Digital Pulse Monitor DPM Panel Installation 10 5 1 2 Digital Pulse Control DPC Panel Installation 10 5 1 3 Final Connections For All Gauge Options 10 5 2 Electrical Connections For Booth Lights...

Страница 4: ...ccumulation which may result in flash over or fire damage The MCB system should not be used for support of personnel or material Operate only in safe and serviceable condition DANGER WARNING CAUTION C...

Страница 5: ...aning in the work environment or as part of your manufacturing process As you review this manual refer to Figure 1 and 2 for assistance in locating unit parts 2 3 AIR FILTERING OPERATION During the ai...

Страница 6: ...2 Revised 03 15 MCB Crossflow Dust Collector Figure 1 MCB Operation Detail 44 10343 0001...

Страница 7: ...3 Revised 03 15 MCB Crossflow Dust Collector Figure 2 Typical MCB Dust Collector With Booth Enclosure Installation 44 10344 0003...

Страница 8: ...to be installed the modules need to be spaced with a 1 gap between side panels A UAS supplied trim strip will bridge the gap between the units 3 To install the trim strip remove all fasteners on the f...

Страница 9: ...5 Revised 03 15 MCB Crossflow Dust Collector Figure 3 MCB Installation Detail 44 10360 0001...

Страница 10: ...wall bracket only has one See Figure 5 2 On the inlet side of all modules remove the top row of fasteners excluding the ones holding the trim strip in place Locate the top panel support bracket using...

Страница 11: ...7 Revised 03 15 MCB Crossflow Dust Collector Figure 4 Motor Installation Diagram 44 10342 0001...

Страница 12: ...8 Revised 03 15 MCB Crossflow Dust Collector Figure 5 MCB Booth Assembly 44 10361 0001...

Страница 13: ...9 Revised 03 15 MCB Crossflow Dust Collector Figure 6 Booth Panel Interlock Connection...

Страница 14: ...l DPC panel remove it from the box Instructions for mounting and connecting the panel are available in the DPM DPC Installation and Owner s Manual The panel should be installed within close proximity...

Страница 15: ...11 Revised 03 15 MCB Crossflow Dust Collector Figure 7 MCB Pressure Gauge Installation 44 10350 0001...

Страница 16: ...a pulse If the delivery capability of your compressed air source cannot return the manifold pressure to above 90 PSIG during the Pulse Delay factory set at 10 sec interval adjust the pulse delay at th...

Страница 17: ...13 Revised 03 15 MCB Crossflow Dust Collector Figure 8 Solenoid Wiring to Pulse Controls 61 10017 0001 REV B...

Страница 18: ...g grease The recommended grease is Chevron SRI 2 Periodically inspect the fan wheel coupling mounting bolts for tightness Re tighten as necessary to ensure the fan wheel does not loosen and come in co...

Страница 19: ...excessive pressure drop over 5 on filter monitor panel Compressed air supply problems Check incoming compressed air for proper pressure 90 110 PSIG 6 4 7 2 BAR pulse flow 1 7 SCF standard cubic feet...

Страница 20: ...16 Revised 03 15 MCB Crossflow Dust Collector 9 ILLUSTRATED PARTS 6 and 9 Foot Wide Module...

Страница 21: ...R BOARD Not Shown SOLENOID ENCLOSURE 4 POSITION SOLENOID ENCLOSURE 6 POSITION SOLENOID REPAIR KIT Not Shown SOLENOID VALVE REPLACEMENT Not Shown LIGHTING FIXTURE 2 BULB FLUORESCENT FINISHING PLUG 2 1...

Страница 22: ...18 Revised 03 15 MCB Crossflow Dust Collector 11 ILLUSTRATED PARTS 3 Foot Wide Module...

Страница 23: ...SURE 2 POSITION SOLENOID REPAIR KIT Not Shown SOLENOID VALVE REPLACEMENT Not Shown FINISHING PLUG 2 1 4 DIA SCREW HEX WASHER 5 16 18 x 3 4 LG SWAGEFORM BLOWER WHEEL BLOWER INLET CONE CARTRIDGE FILTER...

Страница 24: ...uthorized repairs or modifications UAS makes no warranty as to goods manufactured or supplied by others This warranty is subject to any limitations in UAS quotation and may not be modified except by a...

Отзывы: