background image

8

SOLUS-500 EXTRACTOR

PART LIST

1

FP578

Switch, DPDT,with cover

3

78B

Light, red

3A

78

Light, green

5

248

Knob, red

5A

FP544

Potentiometer, heat, w/wires & knob

6

249

Knob, blue

6A

FP543

Potentiometer, pump, w/wires & knob

7

2093A

Switch plate

8

4404C

Mating bar

9

2106

Handle

9A

1590

Grip, handle

10

2105

Wheel, handle

11

FP478

Float assembly, electric

12

801E

Hinge pin, 7”

13

FP594

Tank, Vacuum

13A VC-BLK1 Cover, for vacuum motors

14

2013A

Gasket, vacuum

15

408E

Vacuum motor, 120V

15A 1589

Screen, 1/8 S/S mesh

16

2086A

Lid & ring, vacuum

17

1074

Gasket, vacuum lid

18

FP436

Chain, 8”

19

907

Hose barb, 1-1/2”

20

1130

Strap, Velcro, 9”

21

1060C

Cap, drain hose

22

1518

Hose Clamp

23

1060B

Hose, drain

24

FP582

Tank, Holding

25

FP545

Lid & chain, Holding Tank

26

909A

Latch strike

28

1113

Hose barb, 90°, 1/2” hose

28A 1115

Hose barb, 90°, 3/8” hose

29

925

Hose, 3/8” ID X 20”

31

166

Hose clamp

33

946

Hose, 1/2” ID X 17”

34

207A

Filter, pump inlet

36

See Miscellaneous *

37

918

Heat Sink plate

38

FP361

Motor Speed Control PCB, pump

40

FP225

Vacuum Motor Control PCB

41

2014

Fan, 120V

42

2015

Guard, fan

43

2B1

Screw, 6-32 X 2-1/4”

44

1057B

Power Cord, 12/3, 25 ft

45

1062

Receptacle, AC power in

46

1476

Strap, 17”

49

FP336

PCB mounting track, 4”

50

923B

Dual Cord Sensor PCB

51

198

Hose clamp

52

948B

Motor, DC, for pump

53

FP592

Pump complete, no mtr

54

FP542

Hose assembly, pump to gauge

55

801D

Hinge pin, 4.75”

56

27A

Axle Cap

57

2092

Wheel, 12”

58

910-23.75 Axle rod

60

BUPE-BLK Base compartment

62

905

Castor, 4”

63

2165

Gauge, Pump pressure

64

928

Louver, 3”, gray

65

FP585

Castor Plate

66

908

Latch

67

45

Quick Disconnect, male. 1/4 p.t.

68

115

Washer, fiber

69

116A

Bushing, Teflon

70

92A

Nipple, 1/4 p.t. S/S

71

216

Elbow, brass

72

FP540

Heat Exchanger, complete

73

455

Mount bracket, heater

74

223

Quick Disconnect, male

75

945D

Unloader valve

77

1373A

Hose assembly, heater inlet

78

2183

Hose, S/S, braided, heater outlet

ITEM PART No    DESCRIPTION

MISCELLANEOUS PARTS

*FP194E

Heat repair kit includes thermistor

control, thermistor probe & cutout

950CP

Pump rebuild kit, valves and o-rings

250

Pump rebuild kit, piston and seals

950D

Cam/bearing, pump drive

FP619

Bag, pre-filter for recovery inlet

120V

ITEM PART No    DESCRIPTION

parts in kits are not sold separately

Содержание SOLUS-500

Страница 1: ...er when foaming occurs to prevent vacuum motor damage 2 Keep machine from rain and snow extremes in temperatures and store in a heated location DO NOT let the machine or the wand freeze Do not use out...

Страница 2: ...ped into water return it to a service center Do not pull by the cord use the cord as a handle close a door on the cord or pull the cord around sharp edges or corners Do not run the machine over the co...

Страница 3: ...chine to break up any mineral or chemical build up that may have formed The vacuum motor pump motor and the pump do not require any scheduled maintenance however the motors may require replacement bru...

Страница 4: ...ed to move the machine These handles allow you to tilt the machine back onto it s 12 wheels for easy maneuvering and or for moving on stairways DRAIN HOSE HANDLES VACUUM HOSE BARB FAN VACUUM LID 12 WH...

Страница 5: ...vable at the pressure gauge VACUUM SWITCH 4 This switch will illuminate when the vacuum motors are on The vacuum motors run off of cord 1 CIRCUIT LOCATOR 5 When this light is on it indicates that cord...

Страница 6: ...y 9 When finished with the job vacuum all unused solution into the recovery tank and dump the tank Clean the tanks and filters Clean the tool and hoses Store the machine in a heated location ELECTRIC...

Страница 7: ...36 37 40 38 46 55 57 56 58 62 60 64 66 67 68 53 52 73 70 72 51 50 49 1 5 3 3A 7 6 5A 6A 29 28 31 24 12 16 18 15 14 19 20 22 19 13 17 11 10 75 74 71 77 PUMP 9 26 34 63 54 44 42 41 43 65 15A 9A 13A 23...

Страница 8: ...Vacuum Motor Control PCB 41 2014 Fan 120V 42 2015 Guard fan 43 2B1 Screw 6 32 X 2 1 4 44 1057B Power Cord 12 3 25 ft 45 1062 Receptacle AC power in 46 1476 Strap 17 49 FP336 PCB mounting track 4 50 92...

Страница 9: ...tely closed or seals are damaged Vacuum dome is not seated or is damaged No power to motor Test the Electronic Float Test the switch Test the vacuum motor Test the Vacuum Circuit Board Spraying too lo...

Страница 10: ...10 NOTES SOLUS 500 EXTRACTOR 120V...

Страница 11: ...nd snow extremes in temperatures and store in a heated location DO NOT let the machine or wand freeze Do not use outdoors 3 Do not let the pump run dry 4 Use approved chemicals only NO SOLVENTS 5 Wear...

Страница 12: ...ce center Do not pull by the cord use the cord as a handle close a door on the cord or pull the cord around sharp edges or corners Do not run the machine over the cord Keep the cord away from heated s...

Страница 13: ...achine to break up any mineral or chemical build up that may have formed The vacuum motor pump motor and the pump do not require any scheduled maintenance however the motors may require replacement br...

Страница 14: ...ed to move the machine These handles allow you to tilt the machine back onto it s 12 wheels for easy maneuvering and or for moving on stairways SWITCH PLATE The switches are located on the rear of the...

Страница 15: ...cord 1 PUMP CONTROL 6 This dial controls motor speed and pump pressure Adjust the dial clockwise to increase pressure and counterclockwise to decrease pressure or turn off pump The pump runs off of c...

Страница 16: ...desired temperature IF YOU WANT TO PRE HEAT THE SOLUTION IN THE HOLDING TANK 7 Turn on both the pump and heat recirculation switches NOTE this switch will recirculate heated water back to the holding...

Страница 17: ...recovery tank is full the float system will shut off the vacuum motor to prevent the machine from overflowing The float may not work in foam Always use a defoamer to prevent overflow Once the vacuum m...

Страница 18: ...57 56 58 62 60 64 65 66 67 53 52 35 73 72 50 05 20 2008 49 1 2 5 3 3A 7 6 5A 6A 28 29 28A 31 43 24 10A 10 12 16 18 15 14 19 20 22 19 13 17 74 71 70 75 31 11 47A 70 9 13A 15A 23 31 61 69 68 34 44 Pump...

Страница 19: ...Control PCB 41 2014 Fan 120V 42 2015 Guard fan 43 2B1 Screw 6 32 X 2 1 4 44 1057B Power Cord 12 3 25 ft 45 1062 Receptacle AC power in 46 1476 Strap 17 47 2095 Solenoid 120V recirculation 47A 1278A H...

Страница 20: ...Debris is plugging cleaning tool or vacuum hose Drain gate is not completely closed or seals are damaged Vacuum dome is not seated or is damaged No power to motor Test the Electronic Float Test the sw...

Страница 21: ...11 NOTES SOLUS 500R EXTRACTOR 120V 208 772 0573 800 257 7982 FAX 208 772 0577 VISIT US AT http www usproducts com...

Отзывы: