background image

6

SET-UP AND OPERATION

:

1. Fill the holding tank with clear water and pre-spray with the detergent of your choice (we recommend

a CRI approved chemical).  Mix well.  Although this machine is designed to supply instant hot water,

the addition of warm water to the holding tank would increase heater efficiency.
Never use water above 130º F/54º C in the solution tank.

2. Turn off all the switches.  Plug in cord #1. (This cord runs the pump and vacuum).
3. Attach the priming hose to the machine and place the open end into the tank.
4. Turn on the pump (turn pump pressure dial all the way clockwise) and let it run until the pump is fully

primed (approximately 30 seconds to 1 minute).  Once the pump is primed, turn off the pump and

disconnect the priming hose.  Attach the cleaning hose and tool.

IF YOU WANT HEATED SOLUTION:

5. Plug in the heater cord (identified by “H” on the back of the machine). NOTE:  If the green

circuit indicator light does not illuminate when the heater cord is plugged in, then both cords are

on the same circuit.  Try other outlets until the light comes on.  See Bypass Switch section

(below) if you are unable to get a green light.

6. Turn the heat knob, clockwise, to the desired temperature.

7. Turn on the pump and spray through your tool a few times to fill the lines with solution.  Begin

cleaning.

8. Refill and empty the tanks as necessary.
9. When finished with the job, vacuum all unused solution into the recovery tank, and dump the tank.

Clean the tanks and filters.  Clean the tool and hoses.  Store the machine in a heated location.

ELECTRIC CIRCUIT LOCATOR:
This unique, patented “smart system,” operated by a solid state circuit, will inform the operator when the

two cords are plugged into separate lines by illuminating the green indicator light.  This helps prevent

tripping circuit breakers.

BYPASS SWITCH:
The bypass switch (#6) completely bypasses the circuit locator system.  Use this feature when you

cannot get the green Locator light (#5) to come on and you believe that the two cords are on separate

circuits.

             CAUTION:  If the bypass switch is on when the two cords are plugged into the same

circuit, the circuit breaker in the wall panel may trip.

AUTO VACUUM SHUT-OFF:
When the recovery tank is full, the float system will shut off the vacuum motor to prevent the machine

from overflowing.  The float may not work in foam.  Always use a defoamer to prevent overflow.  Once

the vacuum motor shuts off, the vac switch (#7) must be turned off, the recovery tank emptied, and then

the vacuum switch turned back on (up position) to get the vacuum motor started again.
CAUTION:  Always make sure the float is clean and travels freely before turning on the

machine.  A float that is stuck will cause the vacuum motor to suck in water, resulting in vac

motor damage.

PUMP PRESSURE:
Make sure the cleaning tool is spraying when adjusting the pressure, otherwise the pressure reading will

be inaccurate.

Содержание SOLUS-500

Страница 1: ...er when foaming occurs to prevent vacuum motor damage 2 Keep machine from rain and snow extremes in temperatures and store in a heated location DO NOT let the machine or the wand freeze Do not use out...

Страница 2: ...ped into water return it to a service center Do not pull by the cord use the cord as a handle close a door on the cord or pull the cord around sharp edges or corners Do not run the machine over the co...

Страница 3: ...chine to break up any mineral or chemical build up that may have formed The vacuum motor pump motor and the pump do not require any scheduled maintenance however the motors may require replacement bru...

Страница 4: ...ed to move the machine These handles allow you to tilt the machine back onto it s 12 wheels for easy maneuvering and or for moving on stairways DRAIN HOSE HANDLES VACUUM HOSE BARB FAN VACUUM LID 12 WH...

Страница 5: ...vable at the pressure gauge VACUUM SWITCH 4 This switch will illuminate when the vacuum motors are on The vacuum motors run off of cord 1 CIRCUIT LOCATOR 5 When this light is on it indicates that cord...

Страница 6: ...y 9 When finished with the job vacuum all unused solution into the recovery tank and dump the tank Clean the tanks and filters Clean the tool and hoses Store the machine in a heated location ELECTRIC...

Страница 7: ...36 37 40 38 46 55 57 56 58 62 60 64 66 67 68 53 52 73 70 72 51 50 49 1 5 3 3A 7 6 5A 6A 29 28 31 24 12 16 18 15 14 19 20 22 19 13 17 11 10 75 74 71 77 PUMP 9 26 34 63 54 44 42 41 43 65 15A 9A 13A 23...

Страница 8: ...Vacuum Motor Control PCB 41 2014 Fan 120V 42 2015 Guard fan 43 2B1 Screw 6 32 X 2 1 4 44 1057B Power Cord 12 3 25 ft 45 1062 Receptacle AC power in 46 1476 Strap 17 49 FP336 PCB mounting track 4 50 92...

Страница 9: ...tely closed or seals are damaged Vacuum dome is not seated or is damaged No power to motor Test the Electronic Float Test the switch Test the vacuum motor Test the Vacuum Circuit Board Spraying too lo...

Страница 10: ...10 NOTES SOLUS 500 EXTRACTOR 120V...

Страница 11: ...nd snow extremes in temperatures and store in a heated location DO NOT let the machine or wand freeze Do not use outdoors 3 Do not let the pump run dry 4 Use approved chemicals only NO SOLVENTS 5 Wear...

Страница 12: ...ce center Do not pull by the cord use the cord as a handle close a door on the cord or pull the cord around sharp edges or corners Do not run the machine over the cord Keep the cord away from heated s...

Страница 13: ...achine to break up any mineral or chemical build up that may have formed The vacuum motor pump motor and the pump do not require any scheduled maintenance however the motors may require replacement br...

Страница 14: ...ed to move the machine These handles allow you to tilt the machine back onto it s 12 wheels for easy maneuvering and or for moving on stairways SWITCH PLATE The switches are located on the rear of the...

Страница 15: ...cord 1 PUMP CONTROL 6 This dial controls motor speed and pump pressure Adjust the dial clockwise to increase pressure and counterclockwise to decrease pressure or turn off pump The pump runs off of c...

Страница 16: ...desired temperature IF YOU WANT TO PRE HEAT THE SOLUTION IN THE HOLDING TANK 7 Turn on both the pump and heat recirculation switches NOTE this switch will recirculate heated water back to the holding...

Страница 17: ...recovery tank is full the float system will shut off the vacuum motor to prevent the machine from overflowing The float may not work in foam Always use a defoamer to prevent overflow Once the vacuum m...

Страница 18: ...57 56 58 62 60 64 65 66 67 53 52 35 73 72 50 05 20 2008 49 1 2 5 3 3A 7 6 5A 6A 28 29 28A 31 43 24 10A 10 12 16 18 15 14 19 20 22 19 13 17 74 71 70 75 31 11 47A 70 9 13A 15A 23 31 61 69 68 34 44 Pump...

Страница 19: ...Control PCB 41 2014 Fan 120V 42 2015 Guard fan 43 2B1 Screw 6 32 X 2 1 4 44 1057B Power Cord 12 3 25 ft 45 1062 Receptacle AC power in 46 1476 Strap 17 47 2095 Solenoid 120V recirculation 47A 1278A H...

Страница 20: ...Debris is plugging cleaning tool or vacuum hose Drain gate is not completely closed or seals are damaged Vacuum dome is not seated or is damaged No power to motor Test the Electronic Float Test the sw...

Страница 21: ...11 NOTES SOLUS 500R EXTRACTOR 120V 208 772 0573 800 257 7982 FAX 208 772 0577 VISIT US AT http www usproducts com...

Отзывы: