SPECIFICATIONS:

Rotomolded Body:

Vacuum:

VAC Shutoff:

Pump:

Waterlift:

Heat:

Heater:

Wand:

Weight:

Dimensions:

Lifetime Warranty

Two 5.7”, 3-stage
Electronic
Positive displacement, fully adjustable 0-500 psi
100” -- 170 CFM
Adjustable to 212º F
2000 Watts
Stainless steel, double bend, twin tip
110 lbs.
24W x 28L x 41H (inches)

TROUBLE SHOOTING:

IF THIS OCCURS

CHECK THIS

NO SPRAY

PUMP DOES NOT RUN

Solution tank is empty.

Clogged spray tip.

Pump not running or not primed.

Valve on wand not operating.

Check the brushes in the pump motor.  Replace if necessary.

No power to pump.  Test the Motor Speed Control Circuit Board and potentiometer.

Make sure the Heat Recirculation Switch is turned off.

Debris is plugging cleaning tool or vacuum hose.

Drain gate is not completely closed, or seals are damaged.

Vacuum dome is not seated or is damaged.

No power to motor.

Test the Electronic Float.

Test the switch.

Test the vacuum motor.

Test the Vacuum Circuit Board.

Spraying too long.  Try spraying for 12-15 seconds, or about three strokes.

Heat exchanger needs to be flushed.

Wrong tool being used.  Too much water passing through. Longer hose or larger

diameter hose, than standard.

Heat is not turned on.  Either the green light must be on or the bypass switch must

be turned on.

No power in the wall outlet - check to see if the breaker has tripped.

No power to the bypass switch - check wiring for ‘opens.”

No power out of bypass switch, follow troubleshooting steps to isolate the problem.

Call your distributor for additional help.

LOW SUCTION

NO SUCTION

LOW HEAT

NO HEAT

PUMP WILL NOT PRIME

Содержание SOLUS-500

Страница 1: ...er when foaming occurs to prevent vacuum motor damage 2 Keep machine from rain and snow extremes in temperatures and store in a heated location DO NOT let the machine or the wand freeze Do not use out...

Страница 2: ...ped into water return it to a service center Do not pull by the cord use the cord as a handle close a door on the cord or pull the cord around sharp edges or corners Do not run the machine over the co...

Страница 3: ...chine to break up any mineral or chemical build up that may have formed The vacuum motor pump motor and the pump do not require any scheduled maintenance however the motors may require replacement bru...

Страница 4: ...ed to move the machine These handles allow you to tilt the machine back onto it s 12 wheels for easy maneuvering and or for moving on stairways DRAIN HOSE HANDLES VACUUM HOSE BARB FAN VACUUM LID 12 WH...

Страница 5: ...vable at the pressure gauge VACUUM SWITCH 4 This switch will illuminate when the vacuum motors are on The vacuum motors run off of cord 1 CIRCUIT LOCATOR 5 When this light is on it indicates that cord...

Страница 6: ...y 9 When finished with the job vacuum all unused solution into the recovery tank and dump the tank Clean the tanks and filters Clean the tool and hoses Store the machine in a heated location ELECTRIC...

Страница 7: ...36 37 40 38 46 55 57 56 58 62 60 64 66 67 68 53 52 73 70 72 51 50 49 1 5 3 3A 7 6 5A 6A 29 28 31 24 12 16 18 15 14 19 20 22 19 13 17 11 10 75 74 71 77 PUMP 9 26 34 63 54 44 42 41 43 65 15A 9A 13A 23...

Страница 8: ...Vacuum Motor Control PCB 41 2014 Fan 120V 42 2015 Guard fan 43 2B1 Screw 6 32 X 2 1 4 44 1057B Power Cord 12 3 25 ft 45 1062 Receptacle AC power in 46 1476 Strap 17 49 FP336 PCB mounting track 4 50 92...

Страница 9: ...tely closed or seals are damaged Vacuum dome is not seated or is damaged No power to motor Test the Electronic Float Test the switch Test the vacuum motor Test the Vacuum Circuit Board Spraying too lo...

Страница 10: ...10 NOTES SOLUS 500 EXTRACTOR 120V...

Страница 11: ...nd snow extremes in temperatures and store in a heated location DO NOT let the machine or wand freeze Do not use outdoors 3 Do not let the pump run dry 4 Use approved chemicals only NO SOLVENTS 5 Wear...

Страница 12: ...ce center Do not pull by the cord use the cord as a handle close a door on the cord or pull the cord around sharp edges or corners Do not run the machine over the cord Keep the cord away from heated s...

Страница 13: ...achine to break up any mineral or chemical build up that may have formed The vacuum motor pump motor and the pump do not require any scheduled maintenance however the motors may require replacement br...

Страница 14: ...ed to move the machine These handles allow you to tilt the machine back onto it s 12 wheels for easy maneuvering and or for moving on stairways SWITCH PLATE The switches are located on the rear of the...

Страница 15: ...cord 1 PUMP CONTROL 6 This dial controls motor speed and pump pressure Adjust the dial clockwise to increase pressure and counterclockwise to decrease pressure or turn off pump The pump runs off of c...

Страница 16: ...desired temperature IF YOU WANT TO PRE HEAT THE SOLUTION IN THE HOLDING TANK 7 Turn on both the pump and heat recirculation switches NOTE this switch will recirculate heated water back to the holding...

Страница 17: ...recovery tank is full the float system will shut off the vacuum motor to prevent the machine from overflowing The float may not work in foam Always use a defoamer to prevent overflow Once the vacuum m...

Страница 18: ...57 56 58 62 60 64 65 66 67 53 52 35 73 72 50 05 20 2008 49 1 2 5 3 3A 7 6 5A 6A 28 29 28A 31 43 24 10A 10 12 16 18 15 14 19 20 22 19 13 17 74 71 70 75 31 11 47A 70 9 13A 15A 23 31 61 69 68 34 44 Pump...

Страница 19: ...Control PCB 41 2014 Fan 120V 42 2015 Guard fan 43 2B1 Screw 6 32 X 2 1 4 44 1057B Power Cord 12 3 25 ft 45 1062 Receptacle AC power in 46 1476 Strap 17 47 2095 Solenoid 120V recirculation 47A 1278A H...

Страница 20: ...Debris is plugging cleaning tool or vacuum hose Drain gate is not completely closed or seals are damaged Vacuum dome is not seated or is damaged No power to motor Test the Electronic Float Test the sw...

Страница 21: ...11 NOTES SOLUS 500R EXTRACTOR 120V 208 772 0573 800 257 7982 FAX 208 772 0577 VISIT US AT http www usproducts com...

Отзывы: