SET-UP:

1.

Fill the holding tank with clear water and prespray with the detergent of your choice (we recommend a CRI
approved chemical).  Mix well.  Although this machine is designed to supply instant hot water, the addition

of warm water o the holding tank would increase heater efficiency.  Never use water above 130º F/54º C

in the solution tank.

2. Turn off all the switches.  Plug in cord #1. (This cord runs the pump and vacuum).

3. Attach the priming hose to the machine and place the open end into the tank.

4. Turn on the pump on, and let it run until the pump is fully primed (approximately 30 seconds to 1 minute).

Once the pump is primed, turn off the pump and disconnect the priming hose.  Attach the cleaning hose

and tool.

IF YOU WANT HEATED SOLUTION:

5. Plug in the the heater cord (identified by “H” on the back of the machine). NOTE:  If the green circuit

indicator light does not illuminate when the heater cord is plugged in, then both cords are on the

same circuit.  Try other outlets until the light comes on.  See Bypass Switch section (below) if you are

unable to get a green light.

IF YOU WANT TO PRE-HEAT THE SOLUTION IN THE HOLDING TANK

6. Turn on both the pump and heat recirculation switches. NOTE: this switch will recirculate heated

water back to the holding tank, untili it reaches 125 °F.  At that point, the recirculation will

automatically stop.  If the temperature of the water in the tank drops below 125 °F, and if the

recirculation switch is still turned ON, the system will begin to recirculate the the water again until

it gets back up to 125 °F.  You can choose to let the solution in your holding tank reach 125° or

you can choose to begin cleaning sooner than that.

NOTE: the time that it will take for your solution to reach 125 °F will vary with the temperature of

the solution that you put into the tank, the ambient temperature, the amount of solution in your

tank, etc.

YOU MUST TURN THE HEAT RECIRCULATION SWITCH OFF BEFORE YOU BEGIN

CLEANING, otherwise your pump pressure will be very low.

7. Turn on the pump and spray through your tool a few times to fill the lines with solution.  Begin cleaning.

8. Refill and empty the tanks as necessary.

9. When finished with the job, vacuum all unused solution into the recovery tank, and dump the tank.  Clean

the tanks and filters.  Clean the tool and hoses.  Store the machine in a heated location.  Do NOT freeze.

ELECTRIC CIRCUIT LOCATOR:

This unique, patented “smart system,” operated by a solid state circuit, will inform the operator when the two cords are plugged

into separate lines by illuminating the green, indicator light.  This helps prevent tripping circuit breakers.

BYPASS SWITCH:

The bypass switch (#6) completely bypasses the circuit locator system.  Use this feature when you cannot get the green

Locator light (#5) to come on and you believe that the two cords are on separate circuits.

CAUTION:  If the bypass switch is on when the two cords are plugged into the same circuit, the breaker may trip.

AUTO VACUUM SHUTOFF:

When the recovery tank is full, the float system will shut off the vacuum motor to prevent the machine from overflowing.  The

float may not work in foam.  Always use a defoamer to prevent overflow.  Once the vacuum motor shuts off, the vac switch (#7)

must be turned off, the recovery tank emptied, and then the vacuum swtich turned back on (up position) to get the vacuum

motor started again.

CAUTION:  Always make sure the float is clean and travels freely before turning on the machine.  A float that is

stuck will cause the vacuum motor to suck in water, resulting in vac motor damage.

Содержание SOLUS-310R

Страница 1: ...ent vacuum motor damage 2 Keep machine from rain and snow extremes in temperatures and store in a heated location DO NOT let the machine or wand freeze Use the machine indoors 3 Do not let the pump ru...

Страница 2: ...ped into water return it to a service center Do not pull by the cord use the cord as a handle close a door on the cord or pull the cord around sharp edges or corners Do not run the machine over the co...

Страница 3: ...e to break up any mineral or chemical build up that may have formed U S Products X 1500 is recommended The vacuum motor pump motor and the pump do not require any scheduled maintenance however the mot...

Страница 4: ...d to move the machine These handles allow you to tilt the machine back onto it s 12 wheels for easy manoeuvreing and or for moving on stairways SWITCH PLATE The switches are located on the rear of the...

Страница 5: ...icates that the heater is turned on Once the heater reaches temperature this light will go out Expect this light to be lit most of the time as you clean CARPET UPHOLSTERY SWITCH 5 This rocker switch a...

Страница 6: ...NOTE the time that it will take for your solution to reach 125 F will vary with the temperature of the solution that you put into the tank the ambient temperature the amount of solution in your tank...

Страница 7: ...3 52 35 73 72 50 05 20 2008 49 1 2 3 3A 7 30 29 28 31 43 24 10 10A 12 16 18 15 14 19 20 22 19 13 17 74 69 70 77 31 11 47A 70 1 40 3B 34 47 Pump Inlet Hose 63 54 54A Pump to Gauge Hose 9 23 32 68 Heat...

Страница 8: ...Motor Control PCB 41 2014 Fan 120V 42 2015 Guard fan 43 2B1 Screw 6 32 X 2 1 4 44 1057B Power Cord 12 3 25 ft 45 1062 Receptacle AC power in 46 1476 Strap 17 47 2062 Solenoid pump pressure 120V 47A FP...

Страница 9: ...is is plugging cleaning tool or vacuum hose Drain gate is not completely closed or seals are damaged Vacuum dome is not seated or is damaged No power to motor Test the Electronic Float Test the switch...

Страница 10: ...10 NOTES 208 772 0573 800 257 7982 FAX 208 772 0577 Coeur d Alene Idaho VISIT US AT http www usproducts com SOLUS 310R...

Отзывы: