HEAT RECIRCULATION SWITCH (1):

This switch will energize a solenoid that will pump heated

water back into the holding tank in order to pre-heat the

cleaning solution -- up to 125 °F.

NOTE:  this switch must be turned off to prime the

pump or to begin the cleaning operation.

CIRCUIT LOCATOR (2):

When this light is on, it indicates that cord #2  (Identified

by the red “H” on the back of the extractor.) is on a

separate line from cord #1.  Cord #2 supplies voltage to

the heater allowing it to heat to the temperature range

indicated by the Heat Control dial (#1) on the switch

plate.

BYPASS SWITCH (3):

The bypass switch will illuminate when it is activated and

will completely bypass the circuit locator system.  Use this

system only when the circuit locator light will not turn on

and you know each cord is on a separate circuit.

HEAT INDICATOR LIGHT (4):

When this light is on, it indicates that the heater is turned

on.  Once the heater reaches temperature, this light will

go out. Expect this light to be lit most of the time as you

clean.

CARPET UPHOLSTERY SWITCH (5):

This rocker switch activates a solenoid valve - when it is

turned to Upholstery - that allows most of the pump

pressure to recirculate back to the Holding tank  This

allows you to clean delicate material at low psi (about 75

psi)  When the switch is set to Carpet, the pump operates

without the solenoid and provides about 300 psi to the

cleaning tool. The pump runs off of cord #1.  The pump

spraying pressure will be observable at the pressure

gauge.  This switch does not light up.

PUMP ON/OFF SWITCH (6):

This switch turns the pump on and off.  It will light up

when it is turned on.

VACUUM ON/OFF SWITCH (7):

This switch will illuminate when the vacuum motors are

on.  The vacuum motors run off of cord #1.

FIGURE #1

SWITCH PLATE

1

3

2

4

5

6

7

CAUTION:

THE CIRCUIT BREAKER CAN TRIP IF

BOTH CORDS ARE ON THE SAME

CIRCUIT AND THE BYPASS SWITCH IS
TURNED ON

.

NEVER LET YOUR MACHINE

OR  YOUR WAND FREEZE

Содержание SOLUS-310R

Страница 1: ...ent vacuum motor damage 2 Keep machine from rain and snow extremes in temperatures and store in a heated location DO NOT let the machine or wand freeze Use the machine indoors 3 Do not let the pump ru...

Страница 2: ...ped into water return it to a service center Do not pull by the cord use the cord as a handle close a door on the cord or pull the cord around sharp edges or corners Do not run the machine over the co...

Страница 3: ...e to break up any mineral or chemical build up that may have formed U S Products X 1500 is recommended The vacuum motor pump motor and the pump do not require any scheduled maintenance however the mot...

Страница 4: ...d to move the machine These handles allow you to tilt the machine back onto it s 12 wheels for easy manoeuvreing and or for moving on stairways SWITCH PLATE The switches are located on the rear of the...

Страница 5: ...icates that the heater is turned on Once the heater reaches temperature this light will go out Expect this light to be lit most of the time as you clean CARPET UPHOLSTERY SWITCH 5 This rocker switch a...

Страница 6: ...NOTE the time that it will take for your solution to reach 125 F will vary with the temperature of the solution that you put into the tank the ambient temperature the amount of solution in your tank...

Страница 7: ...3 52 35 73 72 50 05 20 2008 49 1 2 3 3A 7 30 29 28 31 43 24 10 10A 12 16 18 15 14 19 20 22 19 13 17 74 69 70 77 31 11 47A 70 1 40 3B 34 47 Pump Inlet Hose 63 54 54A Pump to Gauge Hose 9 23 32 68 Heat...

Страница 8: ...Motor Control PCB 41 2014 Fan 120V 42 2015 Guard fan 43 2B1 Screw 6 32 X 2 1 4 44 1057B Power Cord 12 3 25 ft 45 1062 Receptacle AC power in 46 1476 Strap 17 47 2062 Solenoid pump pressure 120V 47A FP...

Страница 9: ...is is plugging cleaning tool or vacuum hose Drain gate is not completely closed or seals are damaged Vacuum dome is not seated or is damaged No power to motor Test the Electronic Float Test the switch...

Страница 10: ...10 NOTES 208 772 0573 800 257 7982 FAX 208 772 0577 Coeur d Alene Idaho VISIT US AT http www usproducts com SOLUS 310R...

Отзывы: