9
SPECIFICATIONS:
Rotomolded Body:
Vacuum:
VAC Shutoff:
Pump:
Waterlift:
Heat:
Heater:
Wand:
Weight:
Dimensions:
Lifetime Warranty
Two 5.7”, 2-stage
Electronic
Positive displacement, select Upholstery or Carpet
86” -- 200 CFM
up to 212º F
2000 Watts
Stainless steel, double bend, twin tip
115 lbs.
24W x 28L x 41H (inches)
TROUBLE SHOOTING:
IF THIS OCCURS
CHECK THIS
NO SPRAY
PUMP DOES NOT RUN
Solution tank is empty.
Clogged spray tip.
Pump not running or not primed.
Valve on wand not operating.
Check the brushes in the pump motor. Replace if necessary.
No power to pump. Test the Motor Speed Control Circuit Board and potentiometer.
Make sure the Heat Recirculation Switch is turned off.
Debris is plugging cleaning tool or vacuum hose.
Drain gate is not completely closed, or seals are damaged.
Vacuum dome is not seated or is damaged.
No power to motor.
Test the Electronic Float.
Test the switch.
Test the vacuum motor.
Test the Vacuum Circuit Board.
Spraying too long. Try spraying for 12-15 seconds, or about three strokes.
Heat exchanger needs to be flushed.
Wrong tool being used. Too much water passing through. Longer hose or larger
diameter hose, than standard.
Heat is not turned on. Either the green light must be on or the bypass switch must be
turned on.
No power in the wall outlet - check to see if the breaker has tripped.
No power to the bypass switch - check wiring for ‘opens.”
No power out of bypass switch, follow troubleshooting steps to isolate the problem.
Call your distributor for additional help.
LOW SUCTION
NO SUCTION
LOW HEAT
NO HEAT
PUMP WILL NOT PRIME