FORM NO. 56041928 - ADVANTAGE 100H -
5
SET-UP & OPERATION:
1. Inspect the machine, hoses, and cleaning tools for cleanliness and completeness.
2. Screw the lid on the recovery tank. Close the drain gate.
3. Fill the holding tank with clear water. Connect your tool and hoses.
NOTE: although this machine is designed to supply instant hot water, the addition of warm water to the solution tank would increase heater
ef
fi
ciency. Never use water above 130º F/56º C in the solution tank.
4. Turn off all the switches. Plug the power cords into properly grounded outlets. Do not connect both cords to the same outlet; the green, circuit
locator light
(5)
on the switch plate should light up. If the locator light does not come on, try different outlets until it does.
5. Turn on the pump and let some water
fl
ow through the tool. NOTE: the pump in your Advantage 100H will only run when you spray. A built-in
pressure switch turns the pump off when there is no demand.
6. Turn on the Heat switch
(4)
, and wait two minutes for the heat exchanger to reach temperature.
Pre-spray
traf
fi
c areas with the detergent of your choice. If you choose to add a detergent to the solution tank be sure to mix well and always
follow the use & dilution instructions on the chemical label. Use a chemical with a pH between 5 and 10.
7. Turn on the vacuum
(2)
.
8. Begin
cleaning.
9. Use defoamer any time foaming occurs to prevent damage to the motor or other components.
NOTE: foam will not lift the ball
fl
oat.
10. Monitor the water level in the solution tank. Do not let the pump run dry.
11. When the solution tank gets low, turn off the pump and the vacuum,
fi
ll the solution tank, empty and clean the recovery tank.
12. When
fi
nished with the job, remove any unused solution from the solution tank, and run a few gallons of clean water through the system. Drain
the recovery tank by opening the drain gate over a drain or a bucket. Disconnect the hoses from the cleaning tool.
NOTE: if the green, circuit locator light does not illuminate when the cords are plugged in, then both cords are on the same circuit. Try other outlets
with one of the cords until you get the locator light to come on. NOTE: if the heat switch is turned on when both cords are on the same circuit, the
breaker in the wall may trip.
AUTO VACUUM SHUTOFF:
When the recovery tank is full, the ball
fl
oat will shut-off the suction to prevent the machine from over
fl
owing.
NOTE: the
fl
oat may not work if there is foam in the tank. Always use defoamer to prevent over
fl
ow.
CAUTION!
Always make sure the
fl
oat cage is clean and the ball can travel freely before turning on the machine.