16
Copies the selected percentage range of the source’s total capacity, starting from the initial
sector.
6.3 Copy HPA Mode
This menu contains submenus related to HPA Copy Modes
Scroll to select "Copy HPA Mode”, then press "OK" to view the submenus.
1. Do Not Copy HPA
This menu contains submenu settings for users to default to.
Scroll to select "Copy HPA Area >> Do Not Copy HPA”, then press "OK" view submenu
settings.
⚫
Keep Target HPA
Does not copy HPA data but keeps target device ‘s original HPA setting.
Scroll to select "Keep Target HPA”, then press "OK" to save this setting.
⚫
Clear Target HPA
Does not copy HPA data and clears target device’s HPA setting.
Scroll to select "Clear Target HPA”, then press "OK" to save this setting.
2. Setting Target HPA
Copies HPA setting from source device to target.
Scroll to select "HPA Copy Mode >> Copy HPA Settings”, then press "OK" save this setting.
3. Copy and Setting
Copies HPA setting and data from source device to target.
Scroll to select "HPA Copy Mode >> Copy All HPA”, then press "OK" to save this setting.
Caution
HPA function “Copy and Setting” may change the original parameter of target
devices. To reset it, user must set “Clear HPA at Erase” >> Clear HPA Setting”
and then execute “Erase.”