background image

Integrated Technical Vision Ltd. 

 

http://u-prox.com

 

 

Figure 4

. Distributed network example 

 

It  is  highly  recommended  to  use  VPN  technology  for  computer  network 
connecting central office with sites for additional security. 
It  is  highly  recommended  to  use  routers  with  two  different  technology  Internet 
access channels fir redundancy. 

Algorithm of working in LAN 

1. 

If DHCP - obtaining IP address with the start of the access control panel 

2. 

Update  of IP status of address (announcement and  extension  of reserved 
IP, if DHCP) 

3. 

Determine accessibility of ACS server (IP or DNS name) 

4. 

Periodic sending of test signals 

5. 

If there is, sending of events. Waiting for server commands. 
 

Algorithm of operation on the Internet (local wire net) 

1. 

If  DHCP  -  obtaining  of  IP  address  within  local  network  affiliate  at  panel 
launch 

2. 

Update  of  status  of  IP  addresses  (announcement  and  extension  of 
reserved IP, if DHCP) 

3. 

Determine  possibility  of  access  to  the  Internet  (accessibility  of  given  IP 
address of router) 

4. 

Determine accessibility of ACS server (IP or DNS name) 

5. 

Periodic sending of test signals 

6. 

If there is, send the events. Waiting for server commands. 

7. 

Failure - transition to the second specified IP address of router. 

Содержание IC A

Страница 1: ...1 002 Access control panel U Prox IC A Installation and programming manual ...

Страница 2: ...installation adjustment of external devices and panel configuration are described in Working with the device section Technical support To get warranty and technical support you can apply to authorized service centers situated on the territory of countries enlisted in the warranty card Warranty and technical support performed on the territory of the country where the customer applied for warranty o...

Страница 3: ...des LED s 8 Panel operation 8 Communicator operation 8 Global antipassback 10 System deployment 12 How to work with the device 13 Connection 13 Mount recommendations 13 Communication 14 Wired computer network 14 Panel program order 16 Service maintenance 16 Return to factory settings 16 Switching to programming mode 16 Replacing the device firmware 16 Factory settings 16 ...

Страница 4: ...s and up to 64 antipassback areas Thoroughly elaborated technical and design solutions easy installation communication over a computer Ethernet network non volatile memory and the clock PoE power up ability protecting the communication ports from short circuit over voltage and reverse polarity all allows to use the panel to build a variety of Access Control Systems ACS from the system for a small ...

Страница 5: ...the other one for exit door of this type is called double sided door A door with a reader on one side has only one Access point Entry point and it is called single sided door Antipassback Antipassback function is implemented in access control panels to prevent the situation when user gives his RF ID to another person after passing into the premises If this function is on control panel tracks an RF...

Страница 6: ...a and b Figure 1a U Prox IC A modification 1 Figure 2b U Prox IC A modification 2 Location of jumpers and connectors on control panel board and their function is shown in Fig 2 a and b 1 The Enclosure 2 Ethernet port 3 Micro USB B port 4 Reset button 5 Connectors 4 5 2 3 5 6 1 5 1 2 3 4 1 The Enclosure 2 Reset button 3 Panel board 4 Micro USB B port 5 Ethernet port 6 Connectors ...

Страница 7: ...modification 2 Assignment of the access control panel Contact Name Purpose 12V 12V External 12V power supply connection GND GND USB Connector micro USB B USB Connector For network settings configuration and firmware upgrade Jumper BAT BAT For memory and Real Time Clock backup battery switch Button FUNC FUNC Service button ...

Страница 8: ...tomatic adjustment mode Panel goes to the Normal mode after uploading the configuration To return to the factory settings use the command from the U Prox software or with the routine described in Service Maintenance section Communicator operation U Prox IC A panel operates automatically After the upload from the access control system server the data from the NDC F18 IP U Prox IP100 U Prox IP300 U ...

Страница 9: ...served IP if DHCP 3 Determine accessibility of ACS server IP or DNS name 4 Periodic sending of test signals 5 If there is sending of events Waiting for server commands Algorithm of operation on the Internet local wire net 1 If DHCP obtaining of IP address within local network affiliate at panel launch 2 Update of status of IP addresses announcement and extension of reserved IP if DHCP 3 Determine ...

Страница 10: ...ent of personnel from area to area Also can be tracked the location of the person who has multiple IDs See Figure 5 Figure 5 Allocation of access areas Initially an employee has the location unspecified After the first presentation ID to a reader s location The location unspecified is assigned when registering a new employee or after the system operator command location reset of person is fixed by...

Страница 11: ...P300 U Prox IP400 NDC F18 IP adjusting Only control panels with double sided doors entrance and way out on presentation of ID can be involved in global antipassback In configuring server address 1 has to be the ACS server address In configuring server address 2 has to be the address of the U Prox IC A In the U Prox IP software must be enabled antipassback mode General for the door For each access ...

Страница 12: ...pite it is broadcast announcement it is limited with single range local network and active network equipment That s why the IP addresses of the access control system server are to be set manually for networks with sophisticated topology b The system will warn operator after the receiving of the data package from the new panel Operator must add panel to the system database DB c After the panel adde...

Страница 13: ...epare the place for installation mark and drill mounting holes see Mount recommendations 3 Perform Ethernet wiring 4 Perform power wiring if it is necessary 5 Install and fix the enclosure cover with screws 6 Connect the control panel in the U Prox IP software according to the software manual 7 Download the control panel 8 The device is ready for operation Mount recommendations Place the control p...

Страница 14: ...load from the access control system server the data from the NDC F18 IP U Prox IP100 U Prox IP300 U Prox IP400 panels processed and access event messages are sent to the access control system server Panel Communicator operates in notification mode that means that data transmission to the access control system server is initiated on the access event Operating in the computer network U Prox IC A con...

Страница 15: ... blue 4 blue 5 white blue 5 white blue 6 green 6 yellow 7 white brown 7 white brown 8 brown 8 brown To adjust panel communicator perform Adjust panel network settings don t adjust when use DHCP o IP address o Subnet mask o Gateway router Internet 1 IP address no need in local network o Gateway router Internet 2 IP address miscellaneous o DNS server 1 IP address if data send to the domain name o DN...

Страница 16: ...Service maintenance Return to factory settings To Return to factory settings 1 De power control panel 2 Press and hold FUNC button 3 Supply power to control panel 4 Wait for 10 seconds until LED diode lights and release FUNC button 5 LED diode will flash 6 times that means factory settings restored Switching to programming mode To put access control panel in programming mode do the following 1 Do ...

Страница 17: ...Integrated Technical Vision Ltd http u prox com 17 Reference for device installation modification 2 ...

Отзывы: