Integrated Technical Vision Ltd.
8
Figure 3.
Mixed type (Ethernet & Wi-Fi) local
network connection example
Light emitting diodes (
LED’s)
LED’s from left to right:
Link
LED
Ethernet cable is OK when lit
Act.
LED:
Frequent flashing means data exchange
LED
– bi-color LED
Red flashes 2 times per second
– no connection to the ACS server
Green flashes once per second
– connection to the ACS server is OK
Panel operation
The panels supplied unloaded with factory settings below in document. In this state,
the bi-color LED on the panel flashes red twice per second. To make the panel work
in access control system (ACS) you have to upload a network setting using the
"Configurator" software and USB port or use the automatic adjustment mode.
Panel goes to the “Normal” mode after uploading the configuration.
To return to the factory settings use the command from the U-Prox software or with
the routine described in Service Maintenance section
Communicator operation
U-Prox IC A panel operates
automatically. After the upload
from
the
access
control
system server the data from
the NDC F18 IP, U-Prox
IP100, U-Prox IP300, U-Prox
IP400 panels processed and
access event messages are
sent to the access control
system server.
Panel Communicator operates
in
notification
mode that
means that data transmission
to the access control system
server is initiated on the
access event.
U-Prox IC A panel connected
to the computer network with
wired Ethernet.
Both
local
enterprise
computer network operation
(see
Fig.3)
and
Internet
network
(see Fig.4) operation
via repeaters provided. This
allows the distributed systems of
any scale construction.