Cleaning
NOTICE
Use only U-Line Clear Ice Machine Cleaner
(80-55667-00), available for purchase from
u-line.com or your dealer. It is a violation of
federal law to use this solution in a manner
inconsistent with its labeling. Use of any other
cleaner can ruin the finish of the evaporator and
will void the warranty. Read and understand all
labels printed on the package before use.
U-Line Clear Ice Machine Cleaner is used to remove lime
scale and other mineral deposits. Refer to the following
steps to initiate the self-cleaning cycle.
Never use anything to force ice from the
evaporator. Damage may result.
1.
Turn the ice machine off and allow any ice to melt off
of the evaporator.
2. Remove all ice from the storage bin.
3. Remove evaporator cover.
4. Remove the standpipe by
lifting it up while using
a slight back and forth
motion to loosen it from
the drain hole. The water
in the reservoir will flow
down the drain.
5. Re-install the standpipe into the water trough.
6. Clean the Interior Bin as
follows:
•
Dilute 1-2 oz. of Clear Ice
Machine Cleaner into two
quarts of water.
•
Using a sponge or cloth, clean interior of ice bin,
tubing and door. This cleaner will remove all mineral
deposits and other contaminants from the surfaces.
CAUTION
!
•
Using a bottle brush, clean
out the trough drain tube
and pump tubing where
needed.
7. Turn unit on by pressing .
8. Place unit into CLEAN mode by holding for 5
seconds.
9.
When water begins flowing over the evaporator
(approximately 3 minutes), pour 1-2 oz. of Clear Ice
Machine Cleaner into the water trough. The cleaning
process will last approximately 45 minutes.
10. Dilute 1 tablespoon bleach in 1 gallon of warm water.
Apply this solution to the entire inside of the storage
area. Then rinse thoroughly with water.
The unit will resume operation approximately 15 minutes
after the automated cleaning process is completed. The
water fill valve will energize, fill the water reservoir, and
shut-off after three minutes. The compressor begins to
operate and water flows over the evaporator assembly
(ice mold). Initially, the water flow may not be uniform,
causing uneven sized cubes or water to spill into the ice
storage bin. This is a normal situation that will correct
itself within the first 24 hours of operation.
NOTICE
Discard all ice produced in the first harvest.
Should power to the unit be interrupted during
the self-clean cycle, it will be necessary to
repeat the complete cleaning cycle after power is
restored.
REFRESH KIT
Due to variations in water quality or inadequate
maintenance your unit may become excessively coated
in lime scale or calcium. U-Line offers a cost effective
refresh kit which replaces many interior components and
will return your unit to like new condition. Refresh kits
may be ordered from your local distributor and installed by
your local service company. For information on your local
distributor or service company please visit
www.u-line.com.
Evaporator cover
Standpipe
Evaporator
Water trough
ULIN_0060_A
Brush