background image

SS1095

11

MARINE SERIES

Door Alignment Check and 
Adjustment

IMPORTANT

IMPORTANT

Properly aligned, the door’s gasket should be firmly 
in contact with the cabinet all the way around the 
door (no gaps). Carefully examine the door’s gasket 
to assure that it is firmly in contact with the 
cabinet. Also make sure the door gasket is not 
pinched on the hinge side of the door.

Figure 14

1. Loosen (do not remove) top 

(Figure 14)

 and bottom 

hinge screws.

2. Align door squarely with cabinet.

3. Make sure gasket is firmly in contact with cabinet all 

the way around the door (no gaps). 

4. Tighten bottom hinge screws.

5. Tighten top hinge screws.

Door Reversal

Depending upon the location of the unit, it may be 
desirable to change the side on which the door is 
mounted.

To reverse the door mounting, perform the following:

Figure 15

1. Remove grille (one screw) 

(Figure 15)

.

2. Remove top hinge from cabinet (three screws) 

(Figure 

14)

. Hold door to keep it from falling.

3. Lift the door off the bottom hinge.

Figure 16

4. Remove bottom hinge from cabinet (two screws) 

(Figure 16)

Figure 17

5. Remove screws on opposite side of cabinet 

(Figure 17)

.

ULIN_1044_A

Hinge screws

ULIN_1038_A

Model

SS1095FC

Model

SS1095FD

Grille

screw

ULIN_0122   _A

Содержание SS1095

Страница 1: ...Use and Care Guide M A R I N E S E R I E S Ice Maker Model SS1095...

Страница 2: ...located on the inside rear cover of this guide To validate your warranty the product and its original purchase date must be registered A Warranty Registration Card has been included for this purpose...

Страница 3: ...e Maker 5 Normal Operating Sounds 6 Outdoor Marine and RV Usage 6 Storage Vacation Moving 6 Product Disposal 7 Cleaning and Maintenance 8 Interior Cleaning As Required 8 Defrosting 8 Condenser Cleanin...

Страница 4: ...e off the doors and leave shelves in place so that children may not easily climb inside WARNING SHOCK HAZARD Electrical Grounding Required Never attempt to repair or perform maintenance on the unit un...

Страница 5: ...lways throw away all ice cubes made during the first two to three hours of operation The power switch is located behind the front grille A small opening in the top of the grille Figure 2 is provided t...

Страница 6: ...iciency and maximum sound reduction for its internal working components In spite of this technology your model may make sounds that are unfamiliar Normal operating sounds may be more noticeable becaus...

Страница 7: ...embly and reconnect any lines removed from the water supply valve 7 Disconnect the power cord from its outlet and leave it disconnected until the unit is returned to service 8 Clean and dry the interi...

Страница 8: ...bucket Then place ice bucket back into unit and close door 5 After approximately one hour remove ice bucket and discard water 6 Allow the frost to completely melt naturally Clean the interior and ice...

Страница 9: ...e cleaned at least once each year as follows WARNING Disconnect electrical power to the unit before cleaning the solenoid valve 1 Disconnect electrical power to the unit 2 Shut off the water at the ma...

Страница 10: ...in small increments Too large of an adjustment could cause the unit to malfunction 3 Turn the adjusting screw toward the minus sign clockwise for smaller cubes or toward the plus sign counterclockwise...

Страница 11: ...firmly in contact with cabinet all the way around the door no gaps 4 Tighten bottom hinge screws 5 Tighten top hinge screws Door Reversal Depending upon the location of the unit it may be desirable t...

Страница 12: ...plug Figure 22 from door handle and relocate on opposite side Lift the handle slightly and press on the locking tab then gently pry the hole plug out of the hole being careful not scratch the top cap...

Страница 13: ...y identifying common problems and provide information on possible causes and remedies Most often this will resolve the problem without the need to call for service If Service is Required If you do not...

Страница 14: ...sealing properly Adjust door See MAINTENANCE DOOR ALIGN ADJUST REVERSE Infrequent use of cubes Break apart cubes Noise during operation Copper water supply tubing contacting internal components Caref...

Страница 15: ...d such as fire floods wind and lightening damages incurred or resulting from shipping improper installation unauthorized modification or misuse abuse of the product customer education calls food loss...

Страница 16: ...nit providing complete installation information is available for download at www U Line com Information for custom panel inserts per model including panel size and instructions are available by visiti...

Отзывы: