OPERATING INSTRUCTIONS

COOLING MODE:

In this mode the exhaust adaptor hose MUST be used:

1.  Press the MODE button until the "Cool" indicator lights.

2.  Press the "       " Temp buttons for desired settings.

3.  Press the FAN button for desired fan speed.

HEATING MODE (ON SOME MODELS):

In this mode you do not need to use the exhaust 
adaptor hose:

1.  Press the MODE button until the "Heat" indicator lights.

2.  Press the "       " Temp buttons for desired heat 

settings.

DRY MODE:

In this mode you do not need to use the exhaust 
adaptor hose, BUT the water collected must be 

discharged. See Drainage Section.

1.  Press the MODE button until the "DRY" indicator lights.

2.  The fan will run at low speed and the display will 

show the room temperature.

3.  Keep doors and windows closed for best effect.

AUTO MODE:

Always have the exhaust hose attached in this mode.

 

When you set the air conditioner in AUTO mode, it will 

automatically select cooling, heating (inapplicable for 

cooling-only models), or fan only operation depending 

on what temperature you have selected and the room 

temperature. The air conditioner will control room 

temperature automatically round the temperature point 

set by you. Under AUTO mode, you cannot select the 

fan speed.

FAN MODE:

In this mode there is no need to use the exhaust hose 

or drainage hose. However, if you require stale or 
smokey air to be removed from the room, hook up the 
duct accessories as described in the "EXHAUSTING HOT 
AIR" section.

1.  Press the MODE button until the "FAN" indicator lights.

2.  Press the FAN button to choose the desired fan speed.

3.  The fan will run at the select speed and the display 

will show the room temperature.

TIMER OPERATION:

You can set both delay stop and delay start while unit 

is in ON position or OFF position. When unit is in ON 

position, first press TIMER button to go to delay stop 

setting, then "timer off" light will illuminate. Tap or hold 

the UP arrow (   ) or the DOWN arrow (   ) to change 

delay stop timer at 0.5 hour increments up to 10 hours, 

then at 1 hour increments up to 24 hours. Then press 

the TIMER button to confirm the setting (the control will 

confirm the setting automatically after 5 seconds) and 

go to delay start setting. Use the same way as above 

to set the delay start timing. If you don't need to set 

delay start, press the TIMER button again to exit. After 

5 seconds, the control will automatically change the 

display back to previous temperature display. If you 

want to check remaining time, press the TIMER button. 

The delay start operation automatically selects mode, 

temperature and fan speed the same as last operation 

you set. 

 

When unit is in OFF position, press TIMER button to first go 

to delay start setting, then "timer on" light will illuminate; 

set the delay start and delay stop timing the same way 

as above. 

 

To cancel the timer setting, simply tap (   ) or (   ) button 

to change the timing to 0.0.

SLEEP OPERATION:

In this mode the selected temperature will increase 

by 2°F 30 minutes after the mode is selected. The 

temperature will then increase by another 2°F after an 

additional 30 minutes. This new temperature will be 

maintained for 7 hours before it returns to the originally 

selected temperature. This ends the "Sleep" mode 

and the unit will continue to operate as originally 

programmed. The "Sleep" mode program can be 

cancelled at any time during operation by again 

pressing the "Sleep" button.

 NOTE: This feature is unavailable under 

FAN or DRY modes.

 NOTE: The following instructions are for the Control Panel, the same instructions can be used for the 

Remote Control.

<

<

<

<

<

<

<

<

Содержание H-3778

Страница 1: ... or off Always make sure the RESET button is pushed in for correct operation The power supply cord must be replaced if it fails to reset when either the TEST button is pushed or it cannot be reset A new one can be obtained from the product manufacturer If power supply cord is damaged it CANNOT be repaired It MUST be replaced by one obtained from the product manufacturer OPERATING INSTRUCTIONS ACCE...

Страница 2: ...f rushing air being moved by the fan Gurgling or hissing noise may be heard due to refrigerant passing through evaporator during normal operation Sound of Rushing Air Gurgle Hiss High pitched Chatter Vibration Control Panel Remote Control Room Air Discharge Caster Carrying Handle Both Sides Remote Control Storage Door Exhaust Air Outlet Air Intake Dehumidifying Drain Outlet Bottom Tray Drain Outle...

Страница 3: ...3 and screw the hose to adaptor A See Figure 4 4 Extend the other side of the hose and screw it to adaptor B See Figure 5 5 Slide the assembly onto unit See Figure 6 6 Affix the adaptor B into the window slider kit and seal See Figures 7 8 The hose can be extended from its original length of 15 up to 55 but it is the best to keep the length to minimum required Also make sure that the hose does not...

Страница 4: ...o secure the window slider kit to the window sash See Figure 13 5 Secure the window slider kit to the window stool See Figure 13 A For wooden windows Use screws for securing B For Vinyl Clad windows Use hex head cap screws for securing 6 To secure lower sash in place attach right angle sash lock with 12 77mm screw as shown See Figure 14 NOTE It is difficult to lock the windows with the sash lock f...

Страница 5: ...Figure 18 3 Close the sliding sash securely against the window slider kit See Figure 19 4 Drive two screws to secure the window slider kit to the window sash See Figure 19 5 Drive two screws to secure the window slider kit to the window sash See Figure 19 6 Cut the foam seal to an appropriate length and seal the open gap between the sliding sash and outer window sash See Figure 20 7 To secure the ...

Страница 6: ... and new batteries Do not mix alkaline standard carbon zinc or rechargeable nickel cadmium batteries 2 This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation NOTE The RESET button is depre...

Страница 7: ...ATION You can set both delay stop and delay start while unit is in ON position or OFF position When unit is in ON position first press TIMER button to go to delay stop setting then timer off light will illuminate Tap or hold the UP arrow or the DOWN arrow to change delay stop timer at 0 5 hour increments up to 10 hours then at 1 hour increments up to 24 hours Then press the TIMER button to confirm...

Страница 8: ...temperature sensor has failed Contact Uline Customer Service If the display reads E4 the display panel communication has failed Contact your Uline Customer Service If the display reads P1 bottom tray is full Carefully move the unit to a drain location remove the bottom drain plug and let the water drain away Restart the machine until the P1 symbol disappears If error repeats call for service DRAIN...

Страница 9: ... or fire hazards AIR FILTER CLEANING This unit has three filters filter A B and C Grasp the upper panel tab and take off the filter A behind the grill of the back panel See Figure 24 Remove the lower filter B and C by loosening the screws Take down the air inlet grille then remove the air filter See Figure 25 26 Wash the filter using liquid dishwashing detergent and warm water Rinse filter thoroug...

Страница 10: ...r Refer to Care and Cleaning section page 9 To defrost set to FAN ONLY mode Temperature is set too low for nighttime cooling To defrorst the coil set to FAN ONLY mode Thent set temperature to a higher setting Exhaust duct not connected or blocked See EXHAUSTING HOT AIR section page 3 Air conditioner cooling but room is too warm NO ice forming on cooling coil behind decorative front Dirty air filte...