0513 IH-3778
PAGE 3 OF 10
INSTALLATION INSTRUCTIONS
EXHAUSTING HOT AIR
In the COOLING Mode the appliance must be placed
close to a window or opening so that the warm exhaust
air can be ducted outside.
First position unit on a flat floor and make sure there's
a minimum of 12" clearance around the unit, and is it
within the vicinity of a single circuit outlet power source.
1. Take the hose out from back of the unit.
(See Figure 1)
2. Remove adaptor A from unit by sliding sideways.
(See Figure 2)
3. Extend either side of the hose (See Figure 3)
and screw the hose to adaptor A. (See Figure 4)
4. Extend the other side of the hose and screw it to
adaptor B. (See Figure 5)
5. Slide the assembly onto unit. (See Figure 6)
6. Affix the adaptor B into the window slider kit and seal.
(See Figures 7 & 8)
The hose can be extended from its original length of
15" up to 55", but it is the best to keep the length to
minimum required. Also make sure that the hose does
not have any sharp bends or sags. (See Figure 9)
Take the hose out
Slide out
Extend the side of hose
Slide onto
Window Slider Kit
Minimum:26.6"(67.5cm)
Maxmum:48.5"(123cm)
Vertical
window
Window Slider Kit
Minimum:26.6"(67.5cm)
Maxmum:48.5"(123cm)
Horizontal
window
Figure 5
Figure 7
Figure 8
Figure 2
Figure 1
Figure 3
Figure 4
Figure 9
Figure 6