TEETH REPLACEMENT
1. Loosen screws and nut with an 8 mm wrench and
a 4 mm Allen wrench. (See Figure 15)
2. Remove the magazine assembly. (See Figure 16)
3. Loosen screws with 3 mm Allen wrench.
(See Figure 17)
4. Change teeth one at a time to prevent reverse teeth.
CONNECTING TO AIR
1. Add a few drops of oil into the air inlet.
2. Install a quick connect fitting to the stapler.
3. Regulate the air pressure to attain 70–100 psi.
4. Insert the staples into the tool following the loading
instructions.
5. Reconnect the air hose to the stapler.
6. Grasp the handle with one hand on box in line
with the desired staple location. There is a small
projection on either side of the magazine seat as
an aid in locating the position of the staple.
7. The strongest closure requires staples close to the
ends of the box.
DRIVER REPLACEMENT
1. Disconnect the air supply.
2. Loosen screw and nut with an 8 mm spanner wrench
and a 4 mm Allen wrench. (See Figure 18)
3. Remove the magazine assembly. (See Figure 19)
Figure 15
Figure 16
Figure 17
Figure 18