![U-Line Echelon CLRCO2175B40 Скачать руководство пользователя страница 16](http://html1.mh-extra.com/html/u-line/echelon-clrco2175b40/echelon-clrco2175b40_use-and-care-manual_3422143016.webp)
14
CLR2160, CLRCO2175
plumber to test the water quality and recommend
appropriate treatment.
WARNING
Wear rubber gloves and safety goggles and/or
face shield when handling Ice Machine Cleaner.
CAUTION
Use only U-Line Ice Machine Cleaner (Part No. 41978,
available from your dealer or direct from your local
parts distributor. To locate a parts distributor near
you, visit www.U-LineService.com. It is a violation
of federal law to use this solution in a manner
inconsistent with its labeling. Use of any other
cleaner can ruin the finish of the evaporator and
will void the warranty. Read and understand all
labels printed on the package before use.
U-Line Ice Machine Cleaner is used to remove lime scale
and other mineral deposits. Refer to the following steps
to initiate the self-cleaning cycle.
IMPORTANT
IMPORTANT
• Model CLRCO2175 refrigerator will not operate
during the ice maker cleaning cycle. Remove all
fresh food to prevent spoilage.
• Model CLRCO2175 ice production after the first
harvest may take longer after the cleaning cycle
since restoring the refrigerator temperature will
take precedence over ice production. Once the
refrigerator reaches its set-point temperature, ice
making will resume.
CAUTION
Never use anything to force ice from the
evaporator. Damage may result.
1. Turn the ice maker off (allowing any ice to melt off of
the evaporator) as follows:
Touch and hold the POWER on/off button for 10
seconds
(Figure 20)
. The display will switch from ICE
to OFF to confirm that the ice maker is off.
2. Remove all ice from the storage bin.
3. Remove evaporator cover
(Figure 21)
.
Figure 20
Figure 21
Figure 22
4. Remove the standpipe
(Figure 22)
by lifting it up while
using a slight back and forth motion to loosen it from
the drain hole. The water in the reservoir will flow
down the drain.
5. Re-install the standpipe into the water trough.
6. Clean the Interior Bin as follows:
• Dilute one packet of CLR cleaner into two quarts of
water.
• Using a sponge or cloth, clean interior of ice bin,
tubing and door. This cleaner will remove all
mineral deposits and other contaminants from the
surfaces.
• Using a bottle brush, clean out the trough drain
tube and pump tubing where needed
(Figure 23)
.
7. Place the unit into CLEAN mode by pressing and
holding the POWER button for 10 seconds while
pressing the LIGHT button three times.
Power
Light
Evaporator cover
ULIN_0059_A
Standpipe
Evaporator
Water trough
ULIN_0060_A