CLR2160, CLRCO2175
9
CAUTION
Electrical installation must observe all state and
local codes. This unit requires connection to a
grounded (three-prong), polarized receptacle that
has been placed by a qualified electrician.
The unit requires a grounded and polarized 115 VAC, 60
Hz, 15A power supply (normal household current). An
individual, properly grounded branch circuit or circuit
breaker is recommended. GFCI (ground fault circuit
interrupter) is usually not required for fixed location
appliances and is not recommended for your unit because
a GFCI could be prone to nuisance tripping. However, be
sure to consult your local codes.
See
Figure 13
for recommended receptacle location.
Plugging the unit into a receptacle located behind an
adjacent cabinet will allow the CLRCO2175 to be more
easily serviced with self-diagnostics without disturbing
your installation.
Figure 13
WARNING
SHOCK HAZARD — Electrical Grounding Required.
• Never remove the round grounding prong from
the plug and never use a two-prong grounding
adapter.
• Never use an extension cord to connect power to
the unit.
Note: Unit is shipped in the “ON” position and only needs
to be plugged in to start up.
Figure 14
IMPORTANT
IMPORTANT
Proper air flow (Figure 14) is required for your unit
to operate at its highest efficiently. A grille, located
in the base of the unit, must not be blocked at any
time, or your unit will not perform as expected.
Figure 15
All U-Line units are shipped with controls that are preset.
No initial adjustments are required.
1. Open the door and remove the cover in front of the
evaporator by gently compressing and pulling
forward. This will enable you to observe the water
flow over the evaporator.
2. Check that the overflow tube is inserted securely into
the water trough. PLUG UNIT IN. Once the unit is
powered up, the water fill valve will energize and fill
the water reservoir. The water fill valve shuts off after
approximately 180 seconds (3 minutes). The compressor
begins to operate.
The CLR2160 display will show “ICE” when the unit is on
and will show “OFF” when the unit is off.
The CLRCO2175 display will show the set-point
temperature (38°F) when the unit is on and will show
“OFF” when the unit is off (
Figure 15
) .
Watch the water flow over the evaporator assembly (ice
cube tray) to familiarize yourself with the operation.
Upon initial start-up, water flow ove the evaporator
may be uneven. This may cause uneven sized cubes or
water spilling into the ice storage bin. This is normal
6
ELECTRICAL SPECIFICATIONS
Acceptable
Location
Preferred
Location
for Receptacle
1-1/2"
7"
24"
7
INITIAL STARTUP
ULIN_0080_A
Power
Display
Warmer
Cooler
Light
ULIN_0058_A