Control Operation - Service 4
USER GUIDE
u-line.com
6.
Press to scroll through each relay and DC output.
7.
Press to toggle.
To exit the Relay Toggle menu press to select
“Return to Menu” and press
to confirm.
Input Status
Input status displays the current state of each
available input.
ID
Description
State
Left Door
Left (top) Door Switch
Open - Closed
Right Door
Right (bottom) Door
Switch
(excludes ZWC)
Open - Closed
To access Input Status
1.
Press
to select “Input
Status”.
2.
Press
3.
Press to scroll through available information.
To exit the Input Status menu press to select
“Return to Menu” and press
to confirm outputs.
Outputs
Outputs is used to monitor the state of DC outputs.
ID
Description
Value
L Evap Fan
Left
(top)
Evaporator
Fan
(excludes ZWC)
On - Off
R Evap Fan
Right (bottom)
Evaporator Fan
(excludes ZWC)
On - Off
Condenser Fan
Condenser Fan
On - Off
L Light
Left (top) Light
Off - Low - Med -
High
R Light
Right (bottom)
Light
Off - Low - Med -
High
To access Outputs
1.
Press
to select “Outputs”.
2.
Press
3.
Press to scroll through
available information.
To exit the Input Status menu, press to select
“Return to Menu” and press
to confirm.
Offsets
NOTICE
Do not make an adjustment to this without first
contacting the tech line: (800) 779-2955.
Offsets are used to adjust or correct thermistor
readings. Offset values are added to the current
thermistor reading and are then used by the control
board to determine cooling and defrost cycle times.
Offsets have a range of +/- 10°F. Corrected values
may
be viewed through the customer “All Temps”
menu.
Up
Select
Down
RETURN TO MENU
INPUT STATUS
DOOR OPEN
IN2 OPEN
Up
Select
Down
RETURN TO MENU
OUTPUTS
EVAP FAN=0%
CONDENSER FAN=0%
Up
Select
Down
RETURN TO MENU
OFFSETS
ZONE = 1°F
EVAP = 1°F
Can be displayed in Celsius
.
and
.
and
Содержание 3024DWR
Страница 16: ......
Страница 21: ......
Страница 32: ...RATION USER GUIDE u line com Cleaning 1...
Страница 36: ...USER GUIDE u line com Extended Non Use 1...
Страница 41: ...SAFETY INSTALLATION INTEGRATION OPERATING INSTRUCTIONS MAINTENANCE SERVICE USER GUIDE u line com...
Страница 45: ......