13. Correct use
13.1. General
1. Remove all shipping brackets before installing AIRcel70™.
2. Ensure that no solid foreign objects (e.g., nails, needles, paper clips) or fluids are in contact with the fan top or
openings. Foreign objects can damage device components.
3. If U-Ox™ gets in your eyes, flush with plenty of warm water. Drink plenty of water if accidentally swallowed and
consult a physician. The product is not an irritant; if it comes in contact with the skin, wash with soap and water.
4. Always unplug this product from the appliance before performing any maintenance or cleaning operation.
5. Failure to periodically clean the BioStack™ filter will adversely affect the performance of the appliance. Follow the
instructions in this manual.
6. If the unit has been without power for an extended period of time (e.g. due to a malfunction), replace the water
and U-Ox™.
7. Water should only be poured into the center cylinder, except for adding small amounts.
13.2. Improper use
Any use of the appliance not covered by this manual is considered incorrect. This appliance complies with current
safety regulations. Improper use of the appliance could result in personal injury and property damage. Please read
the operating instructions carefully before operating the appliance. They contain important safety, operating and
maintenance information. This will protect you and prevent damage to the machine itself.
The manufacturer cannot be held liable for damage caused by failure to observe the safety instructions and warnings:
•
Do not place AIRcel70™ in areas subject to freezing temperatures. Frozen pipes may tear or burst, and the reliabi-
lity of electronic equipment may be reduced at temperatures below freezing.
•
Never use cleaning agents containing solvents to clean the AIRcel70™ (e.g., benzene) as this may damage
device components and release hazardous fumes.
•
Do not use cleaning agents containing solvents near or directly on AIRcel70™ (e.g., benzene). Plastic/metal surfa-
ces in contact with the product may be damaged.
•
Do not place any type of object on top of the appliance or inside grill.
•
Do not use abrasive or corrosive materials to clean the exterior surfaces of the appliance.
•
Do not apply any voltage or frequency to the appliance other than those indicated in the specifications.
•
Do not introduce liquids or other substances other than U-Ox™ or water into the tank; this could irreparably affect
the performance of the appliance.
13.3. Cleaning and care
The customer may only carry out the cleaning and care of the device described above. Any other operation shall be
delegated to a technician authorized by the manufacturer.
13.4. Support in case of failure
In case of defects or malfunctions of the device, please contact
.
13.5. Electrical Connection
AIRcel70™ is equipped with a connection cable and a plug. The power plug must always be accessible to disconnect
AIRcel70™ from the main power supply. The device may only be connected to an electrical system that complies with
the applicable regulations.
AIRcel70™ must not under any circumstances be connected to extension cables, e.g. multi-socket plug, in order to
avoid any possible source of danger (fire hazard). The nameplate gives details of the rated input power. Compare
the data on the nameplate with the data from the main power source.
13.6. Handling
If you decide to move the appliance after its installation, be sure to take all appropriate precautions for its safe
handling. In particular, pay attention when lifting the unit, always use both hands, and check that the supporting surfa-
ce is free from sharp or protruding objects. Also remember to ensure a controlled movement to prevent back injury,