safety requirements are fully met for these parts only. The use of non-original parts will impair the function of
the device and does not guarantee safe operation.
5. Improper repairs can lead to unforeseeable risks for the user for which U-Earth is not responsible. Repair work
must only be carried out by technicians authorized by U-Earth. Otherwise, no warranty claim can be made for the
damage caused.
6. If the connection cable is damaged, it must be replaced by technicians authorized by U-Earth in order to
safeguard the user from any danger.
7. In case of failure, the machine must be taken out of operation. During cleaning and maintenance, AIRcel70™ must
be unplugged from the power supply.
8. Do not tilt the device during use. Water leaking into the device may cause a short circuit.
9. Do not place objects on the AIRcel70™.
10. During operation of AIRcel70™, the water level in the reservoir should be checked regularly. Water evaporates
during the bio-oxidation process. The water level should never fall below the minimum level as this will cause the
device to shut down to prevent damage to the pump.
11. If AIRcel70™ is left unused for long periods of time (e.g. during vacations), the water tank must be completely emp-
tied. The device must be disconnected from the power supply.
AIRcel70™ should only be operated with tap water and U-Ox™ (natural enzymes).
Note:
You will get the best air purification results by ensuring continuous 24/7 operation of the AIRcel70™ and a regu-
lar supply of U-Ox™. AIRcel70™ is designed to work non-stop 24/7 and this is the intended mode of operation.
9. Components
Air exhaust, lid / cap, water level sensor, fan, BioStack™ - Biological filter, pump, tub / tank.
10. What's in the box:
•
AIRcel70™ unit
•
12V dc power cable (input voltage 100-240 Volt approx, frequency 50-60 Hz)
•
Pure Air Zone adhesive
•
Instructions for use
11. Using the AIRcel70™
11.1. Installation
To proceed with the installation of AIRcel70™ follow the procedure described below:
Installation operations must take place with no power supply; Remove the AIRcel70™ from the box and store it
in a suitable place or where indicated by your Air Quality Specialist;
1. Lift the cover and place it next to the tank;
2. Disconnect the cable by unscrewing the connector. Do not pull on the connector;
3. Place the lid on a flat surface; you will see the empty middle part, which ends up in the water tank, where water
and the U-Ox™ should be placed;
4. Remove the 2 pieces of tape from the waterplate grid; these tapes are to prevent any damage to the grid during
transport;