EVK-R6 and EVK-L6 - User guide
UBX-21035387 - R03
Appendix
Page 25 of 27
C1-Public
D
Current consumption measurement
Measure the current consumption of the cellular module on the EVK-R6 and EVK-L6 by removing the
jumper socket from the
Cellular VCC supply jumper
(J109 on the ADP-R6 /L6), described in
Cellular VCC supply jumper socket (J109)
to be removed for
LARA-R6 / LARA-L6 module
current consumption measurements
Figure 6: Jumper socket to be removed for cellular module
’s
current consumption measurement
A suitable external digital multi-meter (as the Keysight 34465A, 34410A or 34411A) can be used for
current consumption measurements: in this case, the 3.8 V supply circuit on the EVB will supply the
cellular module, with the digital multi-meter placed in series as illustrated in
LARA-R6 adapter board
LARA-R6
Cellular
module
42
-pi
n
DI
L
B
2
B
c
on
n
ec
to
rs
EVB-WL3
Step - down
Main power switch
(SW400)
12 V
(J400)
3.8 V
VCC jumper
(J109)
VCC
Digital multimeter
DCI
+
–
VCC jumper
(J404)
Figure 7: Block diagram of the setup for
cellular module’s current consumption measurement using a current meter
Alternatively, a suitable external DC power supply with the dynamic current measurement capabilities
(as for example, the portable and cheap Qoitech Otii Arc, or the more accurate Keysight N6705B, or
the models designed for mobile communications Keysight 66319B/D or 66321B/D) can be used for
current consumption measurements, acting also as 3.8 V supply source for the cellular module
mounted on the adapter board, as illustrated in
LARA-R6 adapter board
LARA-R6
Cellular
module
42
-pi
n
DI
L B
2B
c
on
nec
to
rs
EVB-WL3
Step - down
Main power switch
(SW400)
12 V
(J400)
3.8 V
VCC jumper
(J109)
VCC
Power analyzer
PSU
VCC jumper
(J404)
+
GND
GND
Figure 8: Block diagram of the setup for
cellular module’s current consumption measurement
using a DC power analyzer