Power and error displays on the control unit
Symbol
Response
Possible cause
Action
Lights up red
After the first 100 operating
hours, then after every 200 op-
erating hours.
Carried out only by TYROLIT Hydrostress AG
or an authorised representative
Lights up red
Fault:
- current overload
- short circuit
- earth fault Main motor
- defective feed motor
The control unit will not start.
X
Check network connection.
X
Check cable.
X
Replace feed motors.
X
Contact TYROLIT Hydrostress AG customer service.
Lights up red
Defective
- main contactor
- brake resistance
- over current Motor
- CAN fault
- group fault
The control unit will not start.
X
Contact TYROLIT Hydrostress AG customer service.
X
Check network connection.
Lights up red
Over heated
- cooling element
- control unit
- main motor
The control unit will not start.
X
Check cooling. Wait until it can be restarted. Before starting
press the reset button.
X
Avoid direct contact with sun light.
Lights up red
Phase missing
The drive unit will not start or switches off during operation.
X
Check the mains fuse in the distribution box and switch it on
if necessary.
X
Have the site power supply checked.
X
Have the extension cables, plugs and sockets
checked for faults.
Lights up red
The EMERGENCY STOP has been
activated
- CAN fault
X
Deactivate the EMERGENCY STOP.
X
Contact TYROLIT Hydrostress AG customer service.
Lights up red
Feed potentiometer not in zero
position
The control unit will not start.
X
Set the feed potentiometer to
0
.