Power and error displays on the control unit

Symbol

Response

Possible cause

Action

Lights up red

After the first 100 operating 
hours, then after every 200 op-
erating hours.

Carried out only by TYROLIT Hydrostress AG 
or an authorised representative 

Lights up red

Fault:
- current overload
- short circuit 
- earth fault Main motor
- defective feed motor

The control unit will not start.

 

X

Check network connection.

 

X

Check cable.

 

X

Replace feed motors.

 

X

Contact TYROLIT Hydrostress AG customer service.

Lights up red

Defective 
- main contactor
- brake resistance
- over current Motor
- CAN fault
- group fault

The control unit will not start.

 

X

Contact TYROLIT Hydrostress AG customer service.

 

X

Check network connection.

Lights up red

Over heated
- cooling element
- control unit
- main motor

The control unit will not start.

 

X

Check cooling. Wait until it can be restarted. Before starting 
press the reset button.

 

X

Avoid direct contact with sun light.

Lights up red

Phase missing

The drive unit will not start or switches off during operation.

 

X

Check the mains fuse in the distribution box and switch it on 
if necessary.

 

X

Have the site power supply checked.

 

X

Have the extension cables, plugs and sockets  
checked for faults.

Lights up red

The EMERGENCY STOP has been 
activated
- CAN fault

 

X

Deactivate the EMERGENCY STOP.

 

X

Contact TYROLIT Hydrostress AG customer service.

Lights up red

Feed potentiometer not in zero 

position

The control unit will not start.

 

X

Set the feed potentiometer to 

0

.

Содержание WSE2226

Страница 1: ...Operating Instructions Control unit WSE2226 Index 000 Original operating instructions 10991502 en 15 11 2016...

Страница 2: ...T Hy drostress replacement parts can guarantee quality and interchangeability If maintenance work is neglected or carried out inexpertly we will be unable to honour our warranty obligations Any repair...

Страница 3: ...ing machine continuing to run after an acci dent X X Ensure that the EMERGENCY STOP button can be reached quickly Electric shock from live cables and connectors X X Switch off the control unit WSE2226...

Страница 4: ...nnector 12 Reset button 6 Water nipple water inlet 13 Radio remote controller 7 Water connection water outlet Main components of radio remote controller Main components of remote controller 1 Feed pot...

Страница 5: ...ly charged battery is approximately 12 hours A shorter operating period can be expected at low temperatures The reception distance is 25 m Battery operation The battery holder is included in the scope...

Страница 6: ...ed Accessories 1 2x Interchangeable rechargeable batteries No 10984306 2 Rechargeable battery charger No 10984305 Rechargeable battery charger with 10 30 VDC connection No 10984840 3 Remote control ca...

Страница 7: ...upply 9 9 Connectors plugs are clean 9 9 Cables are undamaged X X Connecting the mains and water supply 9 9 The power supply is earthed and fitted with a residual current operated protective device FI...

Страница 8: ...k switch Traverse feed 8 Main motor potentiometer 2 Water On Off 9 Diameter selector switch 3 EMERGENCY STOP 10 Feed joystick 4 Pulse switch control unit 11 Main switch Control unit 5 Starter switch 1...

Страница 9: ...ng the starter switch 5 Warning lights radio and battery at first show red An audible signal sounds simultaneously Indicators flash coloured Second audible signal sounds Indicators show coloured Warni...

Страница 10: ...radio link is interrupted another transmitter range empty battery the systems immediately go into EMERGENCY OFF mode New frequency search You can select the next frequency by switching the start swit...

Страница 11: ...X X Turn the main motor 8 potentiometer to the 0 position X X Press the switch main motor 7 to I X X Select the desired output level see 4 5 X X Turn the main motor 8 potentiometer slowly to 100 power...

Страница 12: ...e controlled via the potentiometers Power control Feed motor potentiometer 6 Main motor potentiometer 8 Adjusting the feed The feed movements are selected with the joystick Adjusting the feed During t...

Страница 13: ...off electric motor 7 On Off main motor X X Turn off cooling water switch 2 Water On Off X X Close water valve on control unit WSE2226 X X Turn the start switch 5 on the remote controller to the 0 posi...

Страница 14: ...n After termination of work Proceed as follows X X Turn the main switch on the control unit WSE2226 to the 0 position X X Withdraw the mains plug Control unit WSE2226 X X Disconnect the water hoses fr...

Страница 15: ...Symbols on the control unit Symbols on the remote controller 1 Service 8 Radio and battery remote control 2 Control unit external fault 9 Cooling water 3 Fault within the control unit 10 Group alarm...

Страница 16: ...X X Contact TYROLIT Hydrostress AG customer service X X Check network connection Lights up red Over heated cooling element control unit main motor The control unit will not start X X Check cooling Wa...

Страница 17: ...o light shows No water flow The control unit will not start motor does not run X X Press the cooling water button LED shows blue Lights up red or flashes Group alarm on the control unit When the pulse...

Страница 18: ...ng work Weekly Annually After faults After damage Electrical system X X Check the condition and cleanliness of electric cables plugs connectors and switches X X X X X X Check the condition and cleanli...

Страница 19: ...Check the plug connection X X Check the power supply Group alarm X X Refer to fault indicator Main motor is not running Main motor potentiometer is in 0 position Defective main motor On Off switch on...

Страница 20: ...ilter is blocked X X Remove filter and clean X X Contact TYROLIT Hydrostress AG customer service Switch for the radio remote controller defective X X Contact TYROLIT Hydrostress AG customer service Un...

Страница 21: ...Frequency converter Max current consumption 38 A Power With 32 A power supply net work 17 kW With 63 A power supply net work 26 kW Internal control voltages Controller remote controller 24 VDC 3 6 VDC...

Страница 22: ...t complies with the following direc tives and standards Applied directives 2006 42 EG 2014 30 EU 2012 19 EU 1999 5 EG Applied standards EN 15027 2007 A1 2009 EN 12100 2010 EN 60204 1 2006 A1 2009 EN 6...

Страница 23: ...TYROLIT Hydrostress AG Page 23 Spare parts 10...

Отзывы: