Power and error displays on the remote controller
Symbol
Response
Possible cause
Action
Flashes red
Rechargeable battery voltage
too low
X
Recharge rechargeable battery.
Flashes rapidly
green
No radio connection
The EMERGENCY STOP has been
activated
X
Switch on the control unit.
X
Defective receiver.
X
No receiver matched connection, see page 5.
No light shows
No water flow
The control unit will not start, motor does not run.
X
Press the cooling water button. (LED shows blue).
Lights up red
or flashes
• Group alarm on the control
unit
• When the pulse switch control
unit is operated, the main mo-
tor On/Off switch is in the po-
sition On
X
Observe control unit fault indicators.
X
Press the control unit reset button.
Lights up
green
The motor is ready to start
No light shows
Contactor not ready
X
Operate control unit pulse switch.
Shows the current power range
Ideally: At the third, orange coloured diode (In iron fourth, red diode).