background image

16

 

 

7. Maintenance

 

 

 

- Thoroughly  clean  the  saw once  per week  (in off circuit  condition) 

.

 

 

 

8. Malfunctions

 

 

 

 

Malfunction

 

 

Possible cause

 

 

Remedv

 

 

Motor does not run

 

 

-  Power cord is defective

 

-  Motor is defective

 

-  Switch is defective

 

 

-  New power cord

 

-  May only be repaired by 

an electrician

 

 

lncorrect saw blade rotation direction

 

 

-  Motor incorrectly polarised

 

 

-  Reverse the phase inverter

 

 

Motor shuts down during sawing, 
but can be restarted after a short 
break

.

 

 

-  Feed too fast

 

 

-  Saw blade blunt

 

 

-  Saw blade worn 

(coating > 2 mm)

 

 

-  Cut with slower feed

 

 

 

-  Sharpen saw blade with 

10- 15 cuts in sand-lime 
bricks

 

 

 

 

No water at saw blade

 

 

-  Pump is not running

 

 

 
 
 
 

-  Line system clogged

 

 

-  Change the safety 

device in the switchbox. 
Only by an electrician 
expert.

 

 

-  Clean line system

 

 
 
 
 
 
 

 

Содержание TME700P

Страница 1: ...Operating manual Spare parts list Stone cutoff saw TME700P Index 000 10995348 en I 16 07 2015...

Страница 2: ...make technical changes without prior notice Copyright 2014 TYROLIT Hydrostress AG CH 8330 Pf ffikon ZH Switzerland All rights reserved in particular copyrighting and translating rights Printing of thi...

Страница 3: ...e location where the machine is used The operating manual must be read and used by any person assigned tasks with the machine such as operation including set up repair of malfunctions during operation...

Страница 4: ...ating manual and be fully aware of the safety requirements and hazards posed by the machine In particular any faults that may compromise safety must be repaired immediately 1 3 Organisational measures...

Страница 5: ...nspections The machine must be inspected annually by an expert 1 3 12 The machine must be thoroughly cleaned before inspection Danger 1 3 13 The power cord must be unplugged before all inspection or r...

Страница 6: ...ions each day check the following condition of the diamond saw blade cracked saw blades must be replaced when in doubt by an expert functional condition of the safety devices adequate cooling water su...

Страница 7: ...alled and checked immediately upon completion of the maintenance and repair work 1 5 2 8 Dispose of fuel and consumable materials and replacement parts in a safe and environmentally friendly manner 1...

Страница 8: ...l stop points for load carrying devices etc by means of the lifting gear in a workmanlike manner Danger 1 7 4 Use only suitable transport vehicles with sufficient lifting capacities Danger 1 7 5 Secur...

Страница 9: ...14 Jack ring Item 15 Switch start Item 16 suspension point 2 2 Protective equipment ltem 5 Saw hood ltem 10 Emergency switch 2 3 Technical data Motor power Operation voltage Currentconsumption Connec...

Страница 10: ...10...

Страница 11: ...ound Remove the packing 3 3 Installation of the saw blade or checking the installation Loose the clamp handle item 7 Lift up the saw head and tighten the clamping lever item 7 Remove the side protecti...

Страница 12: ...12...

Страница 13: ...ound Turn the switch item 12 further to triangle ATTENTION ls the saw blade adequately supplied with cooling water Caution Dry cutting is not permitted lnadequate cooling water results an early wear o...

Страница 14: ...14...

Страница 15: ...ent use replace the water daily and remove the saw sludge Also clean the pump s suction strainer with each water change 5 8 Height adjustment The saw blade height adjustment is needed for cutting thro...

Страница 16: ...trician lncorrect saw blade rotation direction Motor incorrectly polarised Reverse the phase inverter Motor shuts down during sawing but can be restarted after a short break Feed too fast Saw blade bl...

Страница 17: ...17...

Страница 18: ...18...