Operation
Operating Instructions
5-10
PPH25RR*** / 000
5.4.7
Shutting down the Drive Unit PPH25RR***
Proceed as follows
• Switch off the electric motor (main switch of radio remote control)
• Shut off the cooling water (Water On/Off button of radio remote control)
• Close the water valve on the Drive Unit PPH25RR***
• Turn the Start switch on the radio remote control into the 0 position
• Turn the forward/reverse switch on the Drive Unit PPH25RR*** to the 0
position
5.5
After the work
Proceed as follows:
• Unplug the mains plug (Drive Unit PPH25RR***)
• Uncouple the water supply on the Drive Unit PPH25RR***
• Open the water valve on the Drive Unit PPH25RR***
• Blow out the water from all the lines (purge pump)
• Uncouple the hydraulic hoses
• Clean the Drive Unit PPH25RR*** with water
Information
Only shut down the Drive Unit PPH25RR*** with the EMERGENCY
STOP in a genuine emergency.
Information
In order to prevent frost damage, if there is a risk of frost the entire water
system must be emptied and blown out upon finishing work or prior to
extended breaks in the work.