Operating Instructions
Operation
PPH25RR*** / 000
5-5
5.3.4
EMERGENCY STOP
In danger situations the EMERGENCY STOP button must be pressed im-
mediately.
Fig. 5-3
EMERGENCY STOP
1 EMERG. STOP on the Drive Unit PPH25RR***
2 EMERG. STOP on the radio remote control
Deactivating EMERGENCY STOP
Fig. 5-4
Deactivating EMERGENCY STOP
Proceed as follows:
• The following controls must be moved into the 0 position:
- Feed joystick (3)
- Main motor On/Off (5)
• Turn the EMERG. STOP button (1 / 2) clockwise.
• Push the main switch (4) to the ON position.
Information
If the EMERG. STOP is activated on the radio remote control, the LED
pilot lamp flashes quickly.
1
2
1
2
3
4
5