Tynetec ZXT485 Скачать руководство пользователя страница 6

Doc

 

No.

 

FM0706

 

issue

 

D

 

Page

 

6

 

Registering

 

a

 

Pill

 

Dispenser

 

onto

 

an

 

Altec

 

Response

 

local

 

carer

 

alarm

 

unit

 

 

1.

 

Put

 

the

 

Altec

 

Response

 

unit

 

into

 

radio

 

device

 

learn

 

mode…

  

  

 

 

 

 

 

 

 

 

 

 

 

 

 

      

  

 

 

 

 

 

 

 

 

 
 
 
 

 

 

 

 

 

 

 

 
 
 
 
 

 

2.

 

Activate

 

the

 

pill

 

dispenser…

 

 

 

 

 

 

 

 

 

 

               

 
 

 

 

 

 

 

 

 

 

  
  

 

 

 

 

 

 

 

 

 

 

 
 
 

3.

 

Exit

 

the

 

Altec

 

Response

 

radio

 

device

 

learn

 

mode…

 

  

 

 

 

 

 

 

 

 

 

 

 

 

      

  

 

 

 

 

 

 

 

 

 
 
 
 

 

 

 

 

 

 

 

 
 
 
 
 
 

 

4.

 

Check

 

a

 

pill

 

dispenser

 

alarm

 

call

 

is

 

displayed

 

on

 

the

 

Altec

 

Response

 

unit

 

by

 

letting

 

the

 

pill

 

dispenser

 

deliver

 

a

 

dose,

 

DO

 

NOT

 

tilt

  

the

 

unit

 

to

 

TAKE

 

the

 

dose,

 

and

 

let

 

half

 

the

 

AFTER

 

time

 

expire.

 

HINT:

 

to

 

speed

up

 

the

 

test

 

adjust

 

the

 

CLOCK

 

to

 

few

 

minutes

 

before

 

the

 

next

 

dose

 

time

 

and

 

reduce

 

the

 

AFTER

 

time

 

to

 

5

 

minutes.

 

Don’t

 

forget

 

to

 

reset

 

the

 

clock/after

 

time

 

when

 

the

 

test

 

call

 

is

 

complete.

 

 

Deleting

 

a

 

Pill

 

Dispenser

 

from

 

an

 

Altec

 

Response

 

local

 

carer

 

alarm

 

unit

 

 

Press

 

ENTER

 

to

 

activate

 

the

 

wake

up

 

display

 

then

 

ENTER

 

again

 

to

 

display

 

the

 

main

 

menu

 

Press

 

ENTER

 

to

 

select

 

 

Radio

 

Devices

 

  

Press

 

the

 

 

key

 

to

 

select

 

 

Delete

 

Device

 

 

then

 

press

 

ENTER

  

The

 

display

 

will

 

prompt

 

you

 

to

 

Trigger

 

the

 

Sensor

 

Activate

 

the

 

pill

 

dispenser

 

to

 

be

 

deleted

 ‐ 

the

 

display

 

will

 

show

 

the

 

device

 

type

 

and

 

its

 

8

 

digit

 

ID

 

number

 

If

 

this

 

is

 

the

 

device

 

you

 

activated

 

press

 

the

 

 

key

 

to

 

select

  

 

Delete

 

 

then

 

press

 

ENTER

 

If

 

it’s

 

NOT

 

the

 

device

 

you

 

activated

 

press

 

the

 

ENTER

 

key

 

to

 

select

 

 

Reject

 

 

then

 

try

 

again

 

To

 

exit

 

the

 

mode

 

select

 

 

Exit

 

 

then

 

press

 

the

 

ENTER

 

key.

 

 

 

 
 

Refer

 

to

 

the

 

Altec

 

Response

 

installation

 

guide

 

(Doc

 

No.

 

FM0548)

 

provided

 

with

 

the

 

portable

 

alarm

 

unit

 

for

 

more

 

information

 

on

 

programming

 

and

 

testing

 

radio

 

devices.

  

 
 

 

Open

 

the

 

lid,

 

press

 

and

 

hold

 

all

 

3

 

buttons

 

together

 

until

 

TEST

 

is

 

displayed.

 

Press

 

button

 

3

 

and

 

the

 

pill

 

dispenser

 

display

 

will

 

show

 

DEMO

.

 

 

The

 

Altec

 

Response

 

display

 

will

 

show

 

Pill

 

Dispenser

 

and

 

its

 

8

 

digit

 

ID

 

number.

 

Check

 

the

 

ID

 

is

 

correct,

 

press

 

the

 

 

key

 

to

 

select

 

 

Accept

 

 

then

 

press

 

ENTER

.

  

Note:

 

if

 

another

 

device

 

has

 

been

 

picked

up

 

press

 

ENTER

 

to

 

 

Reject

 

 

and

 

try

 

again

.

 

 

The

 

display

 

will

 

show

 

 

Flat

 

,

 

use

 

the

 

 

&

 

 

keys

 

to

 

choose

 

the

 

dwelling

 

type.

  

Press

 

the

 

 

key

 

to

 

select

 

 

No:

 

000000

 

 

then

 

press

 

the

 

ENTER

 

key.

  

Use

 

the

 

 

&

 

 

keys

 

to

 

select

 

each

 

digit

 

of

 

the

 

flat

 

number

 

and

 

the

 

 

&

 

 

keys

  

to

 

move

 

between

 

digits

 

then

 

press

 

the

 

ENTER

 

key.

 

Press

 

 

key

 

several

 

times

 

to

 

select

 

 

Exit

 

 

then

 

press

 

the

 

ENTER

 

key.

  

The

 

display

 

will

 

prompt

 

you

 

to

 

Trigger

 

the

 

Sensor

 

again.

 

 

Press

 

and

 

hold

 

button

 

1

 

to

 

exit

 

the

 

DEMO

 

mode.

 

Press

 

ENTER

 

to

 

activate

 

the

 

wake

up

 

display

 

then

 

ENTER

 

again

 

to

 

display

  

the

 

main

 

menu.

 

 

Press

 

ENTER

 

to

 

select

 

 

Radio

 

Devices

 

  

 

Press

 

ENTER

 

to

 

select

 

 

Learn

 

Device

 

  

 

The

 

display

 

will

 

prompt

 

you

 

to

 

Trigger

 

the

 

Sensor

”.

 

 

You

 

now

 

have

 

20

 

seconds

 

to

 

activate

 

the

 

pill

 

dispenser.

 

From

 

the

 

Learn

 

Device

 

menu

 

select

 

 

Exit

 

 

then

 

press

 

ENTER

.

  

 

From

 

the

 

Radio

 

Devices

 

menu

 

select

 

 

Exit

 

 

then

 

press

 

ENTER

.

 

 

The

 

display

 

will

 

return

 

to

 

the

 

wake

up

 

screen

 

and

 

go

 

blank

 

after

 

10

 

seconds.

 

 

The

 

Altec

 

Response

 

is

 

now

 

back

 

in

 

normal

 

operating

 

mode.

 

 

tynetec 

tynetec 

Содержание ZXT485

Страница 1: ...s ready and pills taken times are also transmitted and logged in the Reach Plus or Advent xt This data can be analysed using Tynetec s iCare software Note Advent xt requires additional hardware Loadin...

Страница 2: ...sets how long the alarm sounds and the pill shutter remains unlocked after the medication is due After AFTER is displayed Press button 2 3 to set the after time 00 05 to 05 00 Press button 1 to end an...

Страница 3: ...rd to demonstrate dispensing the medication The display will show CLOSE and the tray will turn to the locked position Press button 3 to repeat or press and hold button 1 for a few seconds to end This...

Страница 4: ...he 8 digit pill dispenser ID to be deleted after the Beep press to exit Press the key to exit Program Mode the unit will sound a Double Beep and the front light will return to STEADY GREEN The 8 digit...

Страница 5: ...dispenser to be deleted Wait for the Pendant Disabled Enter Flat prompt Press the key and wait for the Ready prompt then press the LINE key to clear the connection Refer to the Advent xt operators ma...

Страница 6: ...R key Refer to the Altec Response installation guide Doc No FM0548 provided with the portable alarm unit for more information on programming and testing radio devices Open the lid press and hold all 3...

Страница 7: ...penser from a Touchsafe Pro Nursecall system Select the pill dispenser ID to be deleted from the Delete Telecare Device pull down list box prefixed with a T31 Details of the pill dispenser selected wi...

Отзывы: