Tynetec ZXT485 Скачать руководство пользователя страница 5

Doc

 

No.

 

FM0706

 

issue

 

D

 

Page

 

5

 

Registering

 

a

 

Pill

 

Dispenser

 

onto

 

an

 

Advent

 

xt

 

warden

 

call

 

system

 

 

1.

 

Put

 

the

 

Advent

 

xt

 

system

 

into

 

radio

 

device

 

learn

 

mode…

  

  

  

 

 

 

 

 

 

 

 

 

 

      

  

 

 

 

 

 

 

 

 

 
 
 
 

 

 

 

 

 

 

 

 
 
 
 
 
 
 

2.

 

Activate

 

the

 

pill

 

dispenser…

 

 

 

 

 

 

 

 

 

 

               

 
 

 

 

 

 

 

 

 

 

  

 
 
 
 
 
 
 

3.

 

Exit

 

the

 

Advent

 

xt

 

system

 

radio

 

device

 

learn

 

mode…

 

  

 

 

 

 

 

 

 

 

 

 

 

 

      

  

 

 

 

 

 

 

 

 

 
 
 
 

 

 

 

 

 

 

 

 
 
 
 
 
 
 

4.

 

Check

 

a

 

pill

 

dispenser

 

alarm

 

call

 

is

 

reported

 

on

 

the

 

warden

 

call

 

system

 

by

 

letting

 

the

 

pill

 

dispenser

 

deliver

 

a

 

dose,

 

DO

 

NOT

 

tilt

 

the

 

unit

 

to

 

TAKE

 

the

 

dose,

 

and

 

let

 

half

 

the

 

AFTER

 

time

 

expire.

 

HINT:

 

to

 

speed

up

 

the

 

test

 

adjust

 

the

 

CLOCK

 

to

 

few

 

minutes

 

before

 

the

 

next

 

dose

 

time

 

and

 

reduce

 

the

 

AFTER

 

time

 

to

 

5

 

minutes.

 

Don’t

 

forget

 

to

 

reset

 

the

 

clock/after

 

time

 

when

 

the

 

test

 

call

 

is

 

complete.

 

 

 

Deleting

 

a

 

Pill

 

Dispenser

 

from

 

an

 

Advent

 

xt

 

warden

 

call

 

system

 

 

Press

 

the

 

LINE

 

key

 

and

 

wait

 

for

 

the

 

Ready

 

prompt.

 

Enter

 

5

 

0

 

0

 

1

 

followed

 

by

 

the

 

 

key.

 

Enter

 

the

 

flat

 

number

 

the

 

pill

 

dispenser

 

is

 

being

 

deleted

 

from

 

followed

 

by

 

the

 

 

key.

 

Activate

 

the

 

pill

 

dispenser

 

to

 

be

 

deleted.

 

Wait

 

for

 

the

 

Pendant

 

Disabled

 

 

Enter

 

Flat

 

prompt.

 

Press

 

the

 

#

 

key

 

and

 

wait

 

for

 

the

 

Ready

 

prompt,

 

then

 

press

 

the

 

LINE

 

key

 

to

 

clear

 

the

 

connection.

 

 
 

 

 
 

Refer

 

to

 

the

 

Advent

 

xt

 

operators

 

manual

 

(Doc

 

No.

 

FM0420)

 

provided

 

with

 

the

 

warden

 

call

 

system

 

for

 

more

 

information

 

on

 

programming

 

and

 

testing

 

radio

 

devices.

  

 
 

 

Using

 

the

 

Manager’s

 

DECT

 

telephone;

 

 

Press

 

the

 

LINE

 

key

 

and

 

wait

 

for

 

the

 

Ready

 

prompt.

 

 

Enter

 

5

 

0

 

0

 

0

 

followed

 

by

 

the

 

 

key.

 

 

Enter

 

the

 

flat

 

number

 

the

 

pill

 

dispenser

 

is

 

being

 

installed

 

in

 

followed

 

by

 

the

 

 

key.

 

 

You

 

now

 

have

 

1

 

minute

 

to

 

activate

 

the

 

pill

 

dispenser.

 

 

Ready”

 

Using

 

the

 

Manager’s

 

DECT

 

telephone;

 

 

Press

 

the

 

#

 

key

 

and

 

wait

 

for

 

the

 

Ready

 

prompt.

 

 

Press

 

the

 

LINE

 

key

 

to

 

clear

 

the

 

connection

 

and

 

the

 

warden

 

call

 

system

 

is

 

now

 

back

 

in

 

normal

 

operating

 

mode.

 

 

Open

 

the

 

lid,

 

press

 

and

 

hold

 

all

 

3

 

buttons

 

together

 

until

 

TEST

 

is

 

displayed.

 

 

Press

 

button

 

3

 

and

 

the

 

display

 

will

 

show

 

DEMO

.

 

 

Wait

 

for

 

the

 

Enter

 

Location

 

Code

 

prompt

 

then

 

press

 

0

 

(no

 

location)

 

followed

 

by

 

the

 

 

key.

  

 

Wait

 

for

 

the

 

Pendant

 

Enabled

 

 

Enter

 

Flat

 

prompt.

 

 

Press

 

and

 

hold

 

button

 

1

 

to

 

exit

 

the

 

DEMO

 

mode.

 

 

Ready”

 

Содержание ZXT485

Страница 1: ...s ready and pills taken times are also transmitted and logged in the Reach Plus or Advent xt This data can be analysed using Tynetec s iCare software Note Advent xt requires additional hardware Loadin...

Страница 2: ...sets how long the alarm sounds and the pill shutter remains unlocked after the medication is due After AFTER is displayed Press button 2 3 to set the after time 00 05 to 05 00 Press button 1 to end an...

Страница 3: ...rd to demonstrate dispensing the medication The display will show CLOSE and the tray will turn to the locked position Press button 3 to repeat or press and hold button 1 for a few seconds to end This...

Страница 4: ...he 8 digit pill dispenser ID to be deleted after the Beep press to exit Press the key to exit Program Mode the unit will sound a Double Beep and the front light will return to STEADY GREEN The 8 digit...

Страница 5: ...dispenser to be deleted Wait for the Pendant Disabled Enter Flat prompt Press the key and wait for the Ready prompt then press the LINE key to clear the connection Refer to the Advent xt operators ma...

Страница 6: ...R key Refer to the Altec Response installation guide Doc No FM0548 provided with the portable alarm unit for more information on programming and testing radio devices Open the lid press and hold all 3...

Страница 7: ...penser from a Touchsafe Pro Nursecall system Select the pill dispenser ID to be deleted from the Delete Telecare Device pull down list box prefixed with a T31 Details of the pill dispenser selected wi...

Отзывы: