![Tynetec Advent XT2 Скачать руководство пользователя страница 55](http://html1.mh-extra.com/html/tynetec/advent-xt2/advent-xt2_installation-manual_1186910055.webp)
Doc No. FM0804 issue 4 Page 55
35. SPECIFICATION - LIFT CALLPOINT (SURFACE ABS)
Tynetec Part No’s
ZXT944
EMC Approval
EN 55022
Safety Approval
EN 60950
Data Connection
RS485 (19200 Baud)
Power Requirement
24V DC @ 2mA (standby)
Audio Channels
2 Handsfree Voice Switched with Digital Volume Control
8 Way Address DIL Switch
Set Binary ID
Loudspeaker
35 Ohm 0.5 Watts
Lift Speech Unit
Surface Mount
Yes
Flush Mount
Not Available
Wipe-clean Tactile Keypad
Yes
Emergency Pull Cord
1.7 metres long Orange Polypropylene with 2 Orange Triangular Grips
Emergency Call Button
Red Halo with red LED illuminated symbol
I’m OK Button
No Function
Privacy Button
No Function
Message Waiting Button
No Function
Test Mode Button
No Function
Audible Reassurance
No
Visual Indication
Red Call LED
Kick Switch Input
Yes - N/O
Lift Company Travelling Cable
4 Core
Lift Speech Unit Mechanical
Enclosure Material
White Polycarbonate base & lid, Silver ABS trim
Flammability Rating
UL 94 V-0 (GWFI 850
o
C)
Ingress Protection Rating
IP20
Dimensions
174mm x 112mm x 49mm (HxWxD)
Weight
280 grams
Lift Interface Mechanical
Enclosure Material
Light Grey ABS (RAL 7035)
Flammability Rating
UL 94 V-0
Ingress Protection Rating
IP54
Dimensions
170mm x 85mm x 34mm (LxWxD)
Weight
208 grams
Environmental
Operating Temperature
0
o
C to +40
o
C
Operating Humidity
10% to 90% RH
Relative Humidity
Non-condensing