![Tynetec Advent XT2 Скачать руководство пользователя страница 48](http://html1.mh-extra.com/html/tynetec/advent-xt2/advent-xt2_installation-manual_1186910048.webp)
Doc No. FM0804 issue 4 Page 48
28. SPECIFICATION - CONTROLLER
Tynetec Part No.
ZXT900
EMC Approval
EN 55022
Safety Approval
EN 60950
Social Alarm Standard
EN 50134
System
Removable Memory
1GB Micro SD Card (Swissbit: SFSD1024N1BN1TO-E-DF-161-STD)
Real Time Clock
Auto-DST adjustment
LED Indicators
Power/Data/Line Seize
Display
5.7” TFT
Touchscreen
Protocols
BS8521/TT92/NOW IP
I/O
Inputs
4 x N/O inputs (switched 0V)
Outputs
4 x N/O relay outputs (125VAC/60VDC/1A rated)
RS232 Ports
1
RS485 Ports
2 (19200 Baud)
USB Ports
2 x USB 2.0
Ethernet Ports
2 x 10/100 BASE-TX
DECT Ports
2
PSTN Ports
2
Features
No. of Network Nodes
510
(includes intercoms, lift/external call points, door panels & NTR’s)
No. of Managers Panels
32
No. of Door Panels
16
No. of Network Receivers
32
No. of Speech Channels
2
Audio Control
HVS (Hands Free Voice-switching) warden call and door entry mode
No. of ARC Tel. Numbers
20
No. of PR Tel. Numbers
3 per intercom
Power Supply
Manufacturer/Model No.
Ecopac RSP-150-27 (Tynetec P/No. W00581)
Input
85-264VAC 47/63Hz
Output
27V DC @ 5.6A (150W)
Efficiency
89.5%
Protection
Overload/Over Voltage/Over Temperature (auto shut-down/recovery)
Mains Lead
1.5m x 2183Y white 0.5mm 3 core cable with IEC 90
o
Free Socket
Rechargeable Battery Type
2 x 12V 5Ah Sealed Lead Acid (Tynetec P/No. F00050)
Battery Standby Time
12 Hours (based on 5 calls/hour on a typical 40 way system)
Mechanical
Enclosure
Polyester Powder Coated 18 SWG Mild Steel (RAL7035)
Mounting
Wall Mount
Ingress Protection Rating
IP40
Dimensions
400mm x 500mm x 80mm (HxWxD)
Weight
11.60 kg
Environmental
Operating Temperature
0
o
C to +40
o
C
Operating Humidity
20% to 90% RH
Relative Humidity
Non-condensing