. MANAGER’S DISPLAY PANEL
INSTALLATION
On power-up the
Manager’s Panel will display the
Home
screen.
Press the
Log On
button and the
Enter Password
box will appear as below;
Select
Engineer
from the drop-down list.
Enter the default password
2371
then press the keypad
Log On
button.
The
System Setup
screen will be displayed as below;
Notice Board
–
enter details of events etc. to be displayed on a separate large screen monitor connected to the HDMI
port. The monitor should have a resolution of 1920x1080p otherwise the Notice Board will not be properly rendered.
Programming
–
allows the site Manager to setup basic system features e.g. activity monitoring, I’m OK, etc. All other
system setup must be performed from the XT2 Controller integral display.
Change Password
–
allows passwords to be changed.
Configure Flats
–
allows
flat labels and the order they are displayed on the Manager’s Panel flat status array to be
changed.
Reset Screen
–
used to clear a panel lock-up.
Database Utility
–
allows the panel data to be copied to/from a USB memory stick.
Panel Settings
–
used by an Engineer to setup what features are available to the user, enter a site name, set panel as
the Controller or Satellite, set XT2 network IP address etc.
Date Time
–
used to set the Windows date and time.
IP Settings
–
used by an Engineer to setup Windows IP addresses.
Reset XT2
–
used to restart the XT2 system.