background image

6

 

 

6.

   

BATTERY  OVERDISCHARGE

: We  highly  recommend  hooking  all 

equipment loads to the controller voltage output. This output will discon-

nect the load if the battery voltage drops below the set voltage and this 

will protect the battery from over

-

discharge. If batteries get completely 

discharged  because  the  equipment  was  connected  directly  to  the  bat-

tery, you will reduce the battery life. Discharged batteries will freeze at 

very low temperatures.

 

7.

  

SOLAR READY:  

The system is solar ready so solar panels can be 

added at any time by connecting them to the PV input through a block-

ing diode. The battery charge controller can handle up to 20A of solar 

which is equivalent to 960W of solar panels max. A single blocking di-

ode  is  needed  to  prevent  reverse  current  from  battery  charger  power 

supply into the solar panels. Blocking diode should be at least 6A/100V 

rated.

 

8.

  

ACCESSORIES

: Tycon

®

  also offers a variety of voltage conversion 

products to meet almost any need. Just visit 

tyconsystems.com

 for 

more info.

 

 

Limited Warranty

 

The UPSPro

®

 products are supplied with a limited 36 month warranty 

which covers material and workmanship defects. This warranty does 

not cover the following: 

 

 

Parts requiring replacement due to improper installation, misuse, 

poor site conditions, faulty power, etc.

 

 

Lightning or weather damage.

 

 

Physical damage to the external & internal parts.

 

 

Products that have been opened, altered, or defaced.

 

 

Water damage for units that were not mounted according to user 

manual.

 

 

Usage other than in accordance with instructions and the normal 

intended use.

 

 

Tycon Systems Inc.

 

14641 S 800 W  Suite A

 

Bluffdale, UT 84065

 

[email protected]

 

PH: 801

-

432

-

0003

 

 

 

 

 

 

 

 

 

 

Содержание UPSPro UPSTL48

Страница 1: ...ights and power circuits Contact with power lines lights or power circuits may be fatal We rec ommend to install no closer than 20 feet to any power lines Safety For your own protection follow these s...

Страница 2: ...et to the pole using U Bolt and or Pole Straps STEP 4 Attach The two 8mm bolts that hold the bottom bracket to the enclo sure Make sure all bolts are tight 8 15 ft lbs STEP 5 Install the three wire fe...

Страница 3: ...ables to the batteries Connect the Temperature probe from the controller to any of the battery terminals The tempera ture sensing lug is just a mechanical connection so it doesn t matter which termina...

Страница 4: ...ed large green connector to the TPDIN SC48 20 Battery Controller and re install the fuses in the battery cables The Battery Charging LED will light for about 60sec onds when power is first applied the...

Страница 5: ...ically controlled fan and vent in the bottom of the enclosure Fan airflow should be toward inside of enclosure 5 BATTERY MAINTENANCE The batteries used in the UPSPro systems don t require any maintena...

Страница 6: ...eded to prevent reverse current from battery charger power supply into the solar panels Blocking diode should be at least 6A 100V rated 8 ACCESSORIES Tycon also offers a variety of voltage conversion...

Страница 7: ...7 NOTES...

Страница 8: ...8 8000050 Rev 4 UPSTL48 UPSPro Qwik Install Guide...

Отзывы: