TECH CORNER

 

 

Additional Information you may find useful

 

1. CONTROLLER: 

The controller will turn off all loads when the battery 

voltage falls below a set value. This value can be set in the user inter-

face. This low voltage disconnect function is needed to preserve the life 

of the batteries.

 

2.

 

MAXIMUM LOAD: 

The maximum load supported by the controller is 

200W. If the load is exceeded the controller will shut down all loads and 

display an error condition. It will automatically reset after the load falls 

below 200W.

 

3.

 

OUTPUT  VOLTAGE: 

The  output  voltage  from  the  controller  on  all 

ports can be set individually to 48V or 24V in the user interface. 

 

4.

 

VENTING: 

The enclosure has vents in the upper back of the enclo-

sure and a thermostatically controlled fan and vent in the bottom of the 

enclosure. Fan airflow should be toward inside of enclosure.

 

5.

  

BATTERY  MAINTENANCE: 

The  batteries  used  in  the  UPSPro

®

  

systems don

t require any maintenance. They should last up to 5 years 

in normal use. 

Note: Never store batteries for any length of time in a 

discharged state or it will kill the battery. 

 

SPECIFICATIONS 

            

Subject to change without notice

 

 

 

UPSTL48

 

Load Voltage 

 

24V/48V Selectable

 

Max Load 

 

200W

 

VAC Input +/

-

 10%

 

115 / 230VAC user selectable 

 

Battery Capacity

 

200Ah or 400Ah

 

Battery Type

 

Non

-

Spillable Sealed Lead Acid —AGM 

 

Battery Life

 

5 Years

 

Over

-

discharge protection

 

45.8V to 47.8 –

 

settable in web interface

  

 

PoE Ports

 

Qty 7 Gigabit  0.645A max per port

 

802.3at (port 1

-

4 only), 48VDC or 24VDC 

or OFF –

 

settable in web interface .

 

Aux Output

 

24V or 48V @ 2.25A Max; 

 

Selectable via Web Interface

  

 

Self Consumption

 

3.5W Typ

 

Enclosure Type

 

Steel—STL

 

Operating Temp

 

-

30°C to +60°C  (

-

22°F to 140°F)

  

 

Содержание UPSPro UPSTL48

Страница 1: ...ights and power circuits Contact with power lines lights or power circuits may be fatal We rec ommend to install no closer than 20 feet to any power lines Safety For your own protection follow these s...

Страница 2: ...et to the pole using U Bolt and or Pole Straps STEP 4 Attach The two 8mm bolts that hold the bottom bracket to the enclo sure Make sure all bolts are tight 8 15 ft lbs STEP 5 Install the three wire fe...

Страница 3: ...ables to the batteries Connect the Temperature probe from the controller to any of the battery terminals The tempera ture sensing lug is just a mechanical connection so it doesn t matter which termina...

Страница 4: ...ed large green connector to the TPDIN SC48 20 Battery Controller and re install the fuses in the battery cables The Battery Charging LED will light for about 60sec onds when power is first applied the...

Страница 5: ...ically controlled fan and vent in the bottom of the enclosure Fan airflow should be toward inside of enclosure 5 BATTERY MAINTENANCE The batteries used in the UPSPro systems don t require any maintena...

Страница 6: ...eded to prevent reverse current from battery charger power supply into the solar panels Blocking diode should be at least 6A 100V rated 8 ACCESSORIES Tycon also offers a variety of voltage conversion...

Страница 7: ...7 NOTES...

Страница 8: ...8 8000050 Rev 4 UPSTL48 UPSPro Qwik Install Guide...

Отзывы: