8
8000071 Rev 1 UPS-ST-600 UPSPro® Qwik Install Guide
6.
BATTERY HOOKUP:
Always connect the battery first and discon-
nect the battery last. The controller should not be run without a battery
connected.
7.
BATTERY MAINTENANCE:
The batteries used in the UPSPro sys-
tems don’t require any maintenance. They should last up to 5 years in
normal use.
Note: Never store batteries for any length of time in a
discharged state or it will kill the battery.
8. BATTERY OVERDISCHARGE
: We highly recommend hooking all
equipment loads to the controller load output. This output will discon-
nect the load if the battery voltage is too low and this will protect the
battery from over-discharge. If batteries get completely discharged be-
cause the equipment was connected directly to the battery, you will re-
duce the battery life.
9.
LOAD OUTPUT:
The LOAD output on the Solar Charge Controller is
unregulated. What that means is the voltage output follows the battery
voltage. This is typically 11-15V for a 12V system and 22-29V for a 24V
system. It is up to the user to make sure the connected load is compati-
ble with these voltages. A voltage regulator can be added to provide
regulated output voltages.
Limited Warranty
The UPSPro
®
products are supplied with a limited 36 month warranty
which covers material and workmanship defects. This warranty does
not cover the following:
▫
Parts requiring replacement due to improper installation, misuse, poor site
conditions, faulty power, etc.
▫
Lightning or weather damage.
▫
Physical damage to the external & internal parts.
▫
Products that have been opened, altered, or defaced.
▫
Water damage for units that were not mounted according to user manual.
▫
Usage other than in accordance with instructions and the normal intended
use.