background image

 

Qwik Install

 

STEP 1: 

Add Grounding Wire Between Door and Enclosure: Remove 

plastic covers on copper studs on 

inside of door and inside of enclo-

sure. Add jumper wire between 2 

copper studs and use copper wash-

ers and nuts to secure.  

STEP 2: 

Remove the bottom cover 

and replace it with the PowerVent™ 

included with the package. Add wire 

feedthrus and any necessary con-

nectors into the bottom PowerVent™ 

plate.  

 

STEP 3:  

Install hole plug in drain 

hole in bottom right corner of the en-

closure.  

STEP 4: 

Mount the DIN rail to the 

door using screws provided. Mount 

any extra equipment to the orange 

backplate and secure the backplate in 

the enclosure. Note: The DIN rail can 

also be mounted to the orange back-

plate or sides of enclosure if desired. 

 

STEP 5: 

If pole mounting the enclo-

sure, assemble the pole mount kit to 

the back of the enclosure and mount 

the enclosure to a pole using the 6 hose clamps provided. The enclo-

sure can also be wall mounted using the 4 holes in the back of the en-

closure. 

 

Содержание UPSPro UPS-ST-600

Страница 1: ...ghts and power circuits Contact with power lines lights or power circuits may be fatal We rec ommend to install no closer than 20 feet to any power lines Safety For your own protection follow these safety rules Perform as many functions as possible on the ground Do not attempt to install on a rainy windy or snowy day or if there is ice or snow accumulation at the install site or if the site is wet...

Страница 2: ...erVent plate STEP 3 Install hole plug in drain hole in bottom right corner of the en closure STEP 4 Mount the DIN rail to the door using screws provided Mount any extra equipment to the orange backplate and secure the backplate in the enclosure Note The DIN rail can also be mounted to the orange back plate or sides of enclosure if desired STEP 5 If pole mounting the enclo sure assemble the pole mo...

Страница 3: ...t this cord to hardwire into the mains You can also mount conduit to the enclosure if local codes require it During operation the charger fan may run This is normal STEP 10 Mount any customer electronics to the inside of the enclo sure Connect any loads to the Solar Controller LOAD output LOAD LOAD Press red SET button to turn on off the LOAD output Note There are multiple cable gland feedthrough ...

Страница 4: ...4 UPS ST12 50 600 1 Battery UPS ST24 50 600 2 Battery UPS ST24 100 600 4 Battery ...

Страница 5: ...ve Regulated Sealed Lead Acid Absorbent Glass Mat AGM Battery Life 5 Years Controller Type 40A MPPT with status display and load control Overcharge Protection 14 4V 28 8V Over discharge protection 11V 22V Over discharge recovery voltage 12 6V 25 2V Controller Self Consumption 1W Enclosure Type Powder Coated Steel Enclosure External Size 24 x 15 x 14 610 x 381 x 356mm Enclosure Internal Size 23 x 1...

Страница 6: ...6 ...

Страница 7: ...mperature For cold temperatures the capacity is reduced by 20 30 3 VENTING The enclosure is vented thru the included PowerVent The fan is thermostatically controlled to turn on when the temperature inside the enclosure exceeds 45C It runs on 12V to 24VDC 4 DUAL INPUTS The UPS ST 600 can be used with AC Power alone or Solar Power alone or a combination of both 5 SOLAR PANEL The MPPT controller used...

Страница 8: ...tery you will re duce the battery life 9 LOAD OUTPUT The LOAD output on the Solar Charge Controller is unregulated What that means is the voltage output follows the battery voltage This is typically 11 15V for a 12V system and 22 29V for a 24V system It is up to the user to make sure the connected load is compati ble with these voltages A voltage regulator can be added to provide regulated output ...

Отзывы: