disc spring that is sealed on both its inside and outside
faces with a Teflon

gasket. The Compression Screw is

bronze and the Deflector is brass.

Inquiries concerning the appropriateness of lead coated
sprinklers for a given corrosive environment should be
submitted to the attention of the Technical Services De-
partment. Lead coated sprinklers are not suitable for use
in open sprinkler applications.

Patents

The following patents are applicable to the Model S190
ECOH Sprinklers:

U.S.A. . . . . . . . . . . . . . . . . . . . . . . 5,366,022
U.S.A. . . . . . . . . . . . . . . . . . . . . . . 5,579,846
U.S.A. . . . . . . . . . . . . . . . . . . . . . . 5,584,344
U.S.A. . . . . . . . . . . . . . . . . . . . . . . 5,609,211
U.S.A. . . . . . . . . . . . . . . . . . . . . . . 5,862,994
U.S.A. . . . . . . . . . . . . . . . . . . . . . . 5,865,256
Other patents are pending.

STAR SPRINKLER

Page 2

1-2.2.40

FIGURE 1

MODEL S190 ECOH

PENDENT AND UPRIGHT SPRINKLERS

WRENCH FLAT

(BOTH SIDES)

SEATING SURFACE

ESCUTCHEON PLATE

1-11/16"

(42.7 mm)

(61.9 mm)

2-7/16"

3/4" NPT

NOMINAL MAKE-IN

1/2" (12.7 mm)

SPRINKLER

FACE OF

FITTING

SURFACE

MOUNTING

1/8"

(3.2 mm)

PLATE

MOUNTING

1-3/8" (34.9 mm)

7/8" (22.2 mm)

3/4" (19.1 mm)

1/4" (6.4 mm)

5/8±1/8"

(15.9±3.2 mm)

CLOSURE

S190

(73.0 mm)

2-7/8" DIA.

2-1/4" DIA.

(57.2 mm)

FIGURE 2

MODEL S190 ECOH PENDENT SPRINKLER

WITH #2088 RECESSED ESCUTCHEON

SPRINKLER FINISH

Temperature

Rating

Bulb

Color Code

Natural

Brass

Chrome

Plated

Polyester

Coated

(All Colors)

135°F/57°C

155°F/68°C

175°F/79°C

Red

Yellow

Orange

Pendent (S2511 & S2611)

Upright (S2510 & S2610)

Recessed (S2511 & S2611)

With #2088 Escutcheon

1, 2, 3

1, 2

Notes:

1. Listed by Underwriters Laboratories, Inc.
2. Listed by Underwriters Laboratories for use in Canada (i.e., C-UL Listed)
3. Approved by Factory Mutual Research Corporation.
N/A: Not Available

TABLE A

LABORATORY LISTINGS AND APPROVALS

(The laboratory listings and approvals only apply to the service conditions

indicated in the Design Criteria section.)

Natural

Brass

Chrome

Plated

Polyester

Coated

(All Colors)

1, 2

1, 2

1, 2, 3

1, 2, 3

200°F/93°C

286°F/182°C

Green

Blue

1, 2, 3

1, 2, 3

1, 2

N/A

Lead

Coated

OBSOLETE

Содержание Star S190

Страница 1: ... is recommended that the end user be consulted with respect to the suitability of these corrosion resistant coatings for any given corrosive envi ronment The effects of ambient temperature concentra tion of chemicals and gas chemical velocity should be considered as a minimum along with the corrosive na ture of the chemical to which the sprinklers will be ex posed WARNINGS The Model S190 ECOH Spri...

Страница 2: ...PRINKLER FACE OF FITTING SURFACE MOUNTING 1 8 3 2 mm PLATE MOUNTING 1 3 8 34 9 mm 7 8 22 2 mm 3 4 19 1 mm 1 4 6 4 mm 5 8 1 8 15 9 3 2 mm CLOSURE S190 73 0 mm 2 7 8 DIA 2 1 4 DIA 57 2 mm FIGURE 2 MODEL S190 ECOH PENDENT SPRINKLER WITH 2088 RECESSED ESCUTCHEON SPRINKLER FINISH Temperature Rating Bulb Color Code Natural Brass Chrome Plated Polyester Coated All Colors 135 F 57 C 155 F 68 C 175 F 79 C ...

Страница 3: ... requirements of NFPA 13 for extended coverage upright and pendent sprinklers FM Approval Requirements The Model S190 ECOH Sprinklers are to be installed in accordance with the applicable Factory Mutual Loss Pre vention Data Sheet for limited use in buildings of specific roof construction and for the protection of certain specific ordinary hazard non storage and or non flammable or combustible liq...

Страница 4: ... Sprinkler Readjust the position of the sprinkler fitting to suit 1 The sprinkler must be installed with the deflector parallel to the mounting surface Pendent sprinklers must be in stalled in the pendent position and upright sprinklers must be installed in the upright position 2 After installing the 2088 mounting plate or other es cutcheon as applicable over the sprinkler pipe threads and with pi...

Страница 5: ...installing contractor or sprinkler manufacturer should be contacted relative to any questions It is recommended that automatic sprinkler systems be in spected tested and maintained by a qualified Inspection Service LIMITED WARRANTY Products manufactured by Tyco Fire Products are war ranted solely to the original Buyer for ten 10 years against defects in material and workmanship when paid for and p...

Страница 6: ...STAR SPRINKLER Page 6 1 2 2 40 7071 S 13th Street Suite 103 Oak Creek WI 53154 www starsprinkler com PRINTED IN U S A 3 01 O B S O L E T E ...

Отзывы: