12
4.2.10 First fasten the flex tube at the bottom tube holder and
afterwards at the top tube holder.
4.2.11 Fasten the strength member connector. Avoid unnecessary
crossing of strength member and loose tube. Attach the cable with the
releasable tie wraps. Note the correct orientation of the tie wraps.
Mount the cover on the flex tube holder.
4.2,12 For cable coming from top use a reverse assembly.
4.2.14 In case of IFC: remove X = 800 mm of outer jacket.
The recommended length of secondary fiber L = 1250-1500 mm.
4.2.13 Kit contents
•
1 metal plate
•
2 strength member conn screws
•
1 drum
•
3 bolts and nuts
•
4 releasable tie-wraps
•
1 edge protection
•
1 foam strip
•
2 tie-wraps
•
2 clips
B
IFC cable