![Tyco Electronics 871087 Скачать руководство пользователя страница 58](http://html1.mh-extra.com/html/tyco-electronics/871087/871087_customers-manual_1186225058.webp)
Air Tools TERMI-POINT
(diverse types)
©2013 Tyco Electronics AMP GmbH, a TE Connectivity company.
All rights reserved.
TE Connectivity, TE connectivity (logo), TERMI-POINT and Tyco
Electronics are Trademarks.
56/ 64
Customer Manual
412-18008 Rev. D1
* Other products, logos and company names mentioned herein may be trademarks of their respective owners
b.
Maintain alignment of tool with post and slowly pull until the indicator ring is in line with
front of tool (Fig. 29).
c.
Clip may slide before indicator ring is visible but at least a half of the clip length
(Fig. 30 / Example A).
Fig. 30: Acceptable terminations
1
½ clip lenghth
2
Slide
3
Lateral movement
d.
Lateral clip movement during test (Fig. 30/ Example B) does not affect the quality of
termination.
2.
Test Tip Tool, Part No. 69544
a.
Thread tip onto Hunter mechanical force gage.
b.
Hook tip squarely against ends of clip with tip engaging end of curls on clip (Fig. 29).
c.
Maintain alignment of gage with post and pull slowly, until gage reaches its maximum
reading (Fig. 29). Gage must be set in “Lock” position to record maximum reading.
d.
Clip may slide no more than a half of clip length before reading is obtained
(Fig. 30 / Example A).
e.
Lateral clip movement during test (Fig. 30 / Example B) does not affect the quality of
termination.
NOTE
(applies to 15.3.1.1. too)
Clips that move more than 1/2 of the clip length should be rejected, test
should be repeated with a new clip!