![Tyco Electronics 871087 Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/tyco-electronics/871087/871087_customers-manual_1186225028.webp)
Air Tools TERMI-POINT
(diverse types)
©2013 Tyco Electronics AMP GmbH, a TE Connectivity company.
All rights reserved.
TE Connectivity, TE connectivity (logo), TERMI-POINT and Tyco
Electronics are Trademarks.
26/ 64
Customer Manual
412-18008 Rev. D1
* Other products, logos and company names mentioned herein may be trademarks of their respective owners
5.
Position post pickups of tool over selected post on pc board or panel and visually align man-
drel of tool withpost (ref. Fig. 11), insert post into post pickups until it is positioned against
mandrel (Fig. 11).
6.
Hold tool firmly against end of post: apply appx. 3 kg of pressure and - keeping tool in align-
ment with post - squeeze trigger with index finger; maintain trigger pressure until forward mo-
tion of push rod stops (clip positioned at selected level on post) and then pull tool away from
pc board or panel before releasing trigger.
7.
Inspect termination.
A properly terminated post should appear as shown in Fig. 12.
For operator’s quality check procedure, refer to GP 2019 (appendix).
Fig. 12: Correct Clip Termination
1
No insulation between wire and post at contact area
2
Conductor must be visible
3
Back end of clip
4
Metal-to-metal-contact between wire and post
5
Front end of clip
6
No insulation silvers permitted
7
Insulation silvers permitted
8
Full lenght of clip curls must grip post
9
Distance
10 Correct
11 Clips must not override
12 Last clip on post
NOTE
A pressure of appx. 3 kg must be applied by the operator against the post
while terminatingthe clip. This pressure is needed to overcome the recoil