Pull all samples as shown in Fig. 21 and record tensile value. The rate of pull should be
slow and uniform (do not jerk). Each sample pulled should move a distance of at least
one half clip lenght with only the peak tensile value recorded.
Fig. 28: Making Samples
1
Pull clip ½ lenghth
2
Hunter spring gauge 50 N
3
Test tool Tipp adapted to hunter gauge
c.
The average and minimum acceptable tensile values shown in the table.
Wire size
0,8 x 2,4 mm Clips
330854er Series
Retentiont
0,8 x 1,6 mm Clips
330495er Series
Retention
AWG
[mm²]
minimum
[N]
averageh
[N]
minimum
[N]
average
[N]
20
0,56
11
16 - 25
-
-
22
0,32
-
-
11
16 - 25
24
0,20
11
16 - 25
11
16 - 25
26
0,12
-
-
11-0
16 - 25
15.2.1.2 Production Test
The following procedure is recommended by Tyco Electronics AMP GmbH to assure a satisfactory level of
quality for TERMI-POINT clip applications:
1.
Visual Examination
Each operator should make a visual inspection of all terminations per Publication GP 2019,
item numbers 1 thru 3.
2.
Tensile Pull Test
a.
The first 5 terminations produced by each operator on every shift should be checked by
using the AMP nondestructive pull test tool. See Instruction sheet IS 1933.
b.
Whenever a reel of clip or a spool of wire is changed, proceed according to item a.
NOTE
Samples should be pulled by hand.