6
CORRECT INSTALLATION. GAS IN FROM THE LEFT SIDE
INCORRECT INSTALLATION. GAS IN FROM THE RIGHT SIDE
8.
GAS INLET
•
The gas inlet of the heater is located on the left side of the unit by design.
•
The heater is NOT to be mounted to where the gas inlet is on the right side as it may cause
damage to the heater and doing so will void the product warranty.
9.
MOUNTING
•
The heater may be mounted at a 0 degree angle or at a maximum of a 30 degree angle in reference to
the floor. The heater must always be horizontal to the floor.
o
WARNING: If the heater is mounted at greater than a 30 degree angle will cause improper
flue exhaust of combustion gases which may result in damage to the front grille.
•
NOTE:
Use only the mounting brackets provided by the manufacturer. Heater must be leveled only
on a
Horizontal Axis
but can be angled to a maximum of 30 degrees in reference to the floor.
DO
NOT
mount the heater on a vertical axis. Such installation is considered unsafe and improper and
will automatically
VOID
the product’s warranty.
•
Clearance around the heater must be maintained for prevent fire hazard and to allow proper
ventilation of the heater. Heater must be in a location that allows uniform air pressure around the
entire heater.
`
ANGLE MOUNTED
HORIZONTAL MOUNTED
HEATER MUST BE INSTALLED IN SUCH A WAY
THAT COMBUSTION EXITS THROUGH TOP VENTS
Vent
30 DEG
Radiant Heat
INCORRECT MOUNTING
OVER 30 DEG
Combustion gases exit
through the front grille.