4. Set up and connect
4.1 Set up the device
•
Place the control panel in a suitable place, with sufficient space for the equipment. Manual, packing list, etc., keep
these documents well.
•
Unpack the monitor, place the supplied material, set it up and connect it.
•
Plug the power cord through the hole on the back of the control panel and into the power strip in the bottom
compartment. Also run the monitor cable through the hole and connect to the computer.
•
Unpack the printer (not included), store, place, and connect the supplied material. Connect the USB printer cable to
the computer plug the power cable into the extended-voltage socket in the lower compartment of the control panel.
Insert ink cartridges.
4.2 Connect the device
•
Connect the power cable.
•
Push the ON button on the computer
•
Push the ON button on the monitor
•
Push the ON button on the printer
•
The unit is correctly connect when all systems are working fine
4.3 Check the connection
•
Drive a vehicle on the vehicle lift or over the pit so that the front wheels are centered on the turntables, apply the
handbrake. To protect the turntables from twisting, remove the pins on the turntables only after starting the vehicle.
•
Attach the wheel clamp to the wheels and tighten with the knob. The pins of the wheel clamps should sit on the outer
or inner edge of the rim flange, depending on the rim type.
Make sure the height of each clamp is the same and avoid mounting on deformed areas.
•
Install the measuring head on the correct wheel brackets according to the defined positions.
See the following picture:
•
Adjust the measuring heads.
•
Restart the computer and run the axis measurement program. On the main screen, press the [System] button (
F5
),
then press the [Sensor Information] button (
F6
).
Check the connection between the computer and the measuring heads is normal and the indicator for the
Measuring heads is normal.
The connection check succeeds if all the above steps are normal.
Содержание TW 115
Страница 1: ......
Страница 2: ...TWIN BUSCH GmbH Printing errors mistakes and technical changes reserved by TwinBusch Germany 2 ...
Страница 24: ...TWIN BUSCH GmbH Printing errors mistakes and technical changes reserved by TwinBusch Germany 24 ...
Страница 48: ...TWIN BUSCH GmbH Printing errors mistakes and technical changes reserved by TwinBusch Germany 48 My notes ...
Страница 49: ...TWIN BUSCH GmbH Printing errors mistakes and technical changes reserved by TwinBusch Germany 49 My notes ...
Страница 50: ...TWIN BUSCH GmbH Printing errors mistakes and technical changes reserved by TwinBusch Germany 50 My notes ...
Страница 51: ...TWIN BUSCH GmbH Printing errors mistakes and technical changes reserved by TwinBusch Germany 51 ...
Страница 52: ...TWIN BUSCH GmbH Printing errors mistakes and technical changes reserved by TwinBusch Germany 52 ...