Slots
Your CORIOmaster2 has 17 slots.
Slots in area A are for input modules, slots in area B are for output modules. You can have up to eight input
modules and up to seven output modules.
Slot 13 is for an S/PDIF and analog audio module, CM2-AUD-2IN-3OUT
Slot 14 is for a CPU module.
Rules for placing input modules
Standard bandwidth input modules can go in any position in column A and B, slots 1, 2, 4, 5, 7, 8, 10, and 11.
High bandwidth input modules can only go in column B, slots 2, 5, 8, and 11.
Do not insert high bandwidth input modules in column A. The device and module can be damaged.
Rules for placing output modules
Output slots are arranged into groups. Each group has the same amount of bandwidth. You must either:
n
Fill all the slots of a group with modules
You can either fill all the slots with output modules, or you can fill empty slots in the group with bonding
modules.
OR
n
Leave all the slots of a group empty
You don't need to use bonding modules in groups that contain no output modules.
Place output modules in the first slot of each group first, starting with group C, slot 17. Fill empty slots with
bonding modules.
Groups are linked by bandwidth and also by canvases in CORIOgrapher. You can only use the outputs in a single
group together on the same canvas. You can use more than one group on the same canvas, but if you want to use
more than one canvas, you must use more than one group.
PDF-CM2-547-V1.0 tvONE