Hangzhou Tuya Information Technology Co., Ltd. 9
V1.0.0
3.3 RF Current Consumption
Table 3-3 RF current consumption
Working
Status
Parameter
Average
Value
Maximum
Value
(Typical
Value)
Unit
Mode
Rate
TX Power/
Receiving
TX
250
kbit/s
+20 dBm
200
210
mA
250
kbit/s
+10 dBm
62
64
mA
250
kbit/s
+0 dBm
26
28
mA
RX
250
kbit/s
Constant
receiving
10
12
mA
250
kbit/s
Constant
receiving
10
12
mA
250
kbit/s
Constant
receiving
10
12
mA
3.4 Working Current
Table 3-4 Working current
Working Mode
Working Status
(Ta = 25°C)
Average Value
Maximum Value
(Typical Value)
Unit
EZ
The module is in
EZ mode.
10
40
mA
Connected and
idle
The module is
connected to the
network.
4.2
5
mA
Deep sleep
mode
The module is in
deep sleep mode,
with 64 KB flash
memory.
5
N/A
μA