Piping
Manual 1861 Rev C p/n 001861 0000
AIR-WATER RADIATOR
This system is an air-cooled version with a cooling water total recovery system. A centrifugal pump circulates
the cooling water from the SDV vacuum pump to a radiator-fan unit. To monitor the adequacy of the cooling
water flow and the cooling water discharge temperature, install a flow indicator, flow switch on the cooling
water supply line and a temperature gauge (or switch) at the cooling water discharge line.
For SDV-120, the silencer is not jacketed. Hence, the cooling water circuit is not extended to the process
exhaust silencer (
see Figure 3-3
).
S
FI
MOTOR
SILENCER
PROCESS
INLET
PI
FSL
TI
PROCESS
DISCHARGE
SILENCER
DRAIN
COOLING
WATER
DRAIN
VG
MOTOR
MOTOR
TI
Figure 3-3 – Typical Process and Inlet Discharge for SDV-120 Models with Fan-Cooled, Re-circulated Cooling Water System