16
Set sensor description
successfully.
Failed SMS reply:
If the sensor description is invalid (for example, it is all numeric), the device will
send a notification message via SMS stating “Invalid sensor description, please
rename the sensor.”
3.5.2 Bind a sensor with the camera(s)
Authority:
Super-Administrator
number and
Administrator
number.
Description:
After connecting a fixed sensor to the host and in order to trigger the camera(s) to
take a picture when the sensor alarms, it must be bound to the appropriate
camera(s). Then when the sensor alarms, the host will send out MMS alarm
messages as well as SMS message to the user(s).
Command:
The user must edit and send the following SMS command to the device in order
to:
Bind a sensor with the camera(s)
:
(5)
#40#SensorNumber#CameraNumber#.... CameraNumber#
Bind a sensor with all camera(s)
:
(6)
#40#SensorNumber#
•
SensorNumber
is in the range of “S1” to “S4”. It should be corresponding with
the number of Sensor Signal Input on the host.
SensorNumber
can be
replaced with
SensorDescription.
•
CameraNumber
should be a one-digit number and in the range of “1” to “4”. It
should be the camera number which will be bound with the sensor. A sensor
can be bound with up to eight cameras.
CameraNumber
can be replaced with
CameraDescription.
☺
Successful SMS reply:
The sensor * associate with camera *** successfully.
3.5.2 Remove a sensor from the camera(s)
Authority:
Super-Administrator
number and
Administrator
number.
Description: